ABB RHD 16000-30 Інструкція з експлуатації - Сторінка 5

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Контролер ABB RHD 16000-30. ABB RHD 16000-30 17 сторінок. Electrical part turn actuators for continuous modulating control (contrac)

7. Lubrication

7.1 Mounting position and filing capacity

1)
2)
1)
2)
Figure 2: Mounting position RHD8000 / RHD16000;
Mounting position RHD8000
Minimum oil quantity; approx. [l]
Min. oil level [mm] under inspection
screw
Mounting position RHD16000
Minimum oil quantity; approx. [l]
Min. oil level [mm] under inspection
screw
Table 2:
The arrow indicates the position of the inspection screw 1) and the vent screw 2). After
having mounted the actuator, replace the highest inspection screw with the separately
delivered vent screw.

7.2 Lubricants

Ambient temperature
- 10°C ... + 65°C
- 30°C ... + 50°C
Table 3: lubricants
1)
IMB 3
IMV 5
1) = inspection screw, 2) = venting screw
IMB 3
57
135
IMB 3
88
155
Oil types
Oil type used by manufac-
turer for first filling
ESSO Spartan EP 220
(L-CKC to ISO TR 3498)
Mobil SHC 629
2)
IMB 8
1)
2)
IMV 6
IMB 6
IMB 7
55
74
215
45
IMB 6
IMB 7
contact manufacturer for other mounting orientation
Possible other oil types
Aral Degol BMB 220 BP
Energol
GR-XP 220
Shell Omala 220
Mobilgear 630
------------
1)
2)
1)
2)
IMB 6
IMB 7
IMB 8
IMV 5
61
52
110
80
IMB 8
IMV 5
IMV 6
53
85
IMV 6
5