Cres Cor H-339-1813C-GML Інструкція з експлуатації та технічного обслуговування - Сторінка 3
Переглянути онлайн або завантажити pdf Інструкція з експлуатації та технічного обслуговування для Комерційне харчове обладнання Cres Cor H-339-1813C-GML. Cres Cor H-339-1813C-GML 4 сторінки. Holding cabinet
5925 Heisley Road • Mentor, OH 44060-1833
HOW TO REVERSE DOOR HARDWARE
FOR OPPOSITE HAND (Refer to Fig. 3 [hinge]):
1.
Pop off hinge covers with screwdriver.
2.
Remove screws from hinges to cabinet; remove door
and unscrew latch strike from cabinet.
3.
Remove hinges, latch and all remaining screws from
the right and left side of door. Keep all screws.
4.
Re-mount hinges and latch in the same hole pattern on
the opposite sides of the door. Plug all extra holes with
screws.
5.
Remove all screws from the front sides of cabinet (not
the top and bottom).
6.
Hold door up to cabinet and screw hinges to the
cabinet.
7.
Open door and re-mount the latch strike to cabinet.
8.
Plug all extra holes with screws and snap on the hinge
covers
.
REPLACEMENT PARTS:
DESCRIPTION
Cord Set......................................................
Switch......................................................... 0808-113
Heater
Kit....................................................0811-066-K
Thermostat
Kit............................................0848-062-K
Terminal Block...........................................
Thermometer...............................................5238-030
Door Latch
Kit............................................1006-122-01-K
Strike
Kit.....................................................1006-122-02-K
Hinge Kit....................................................
Gasket Kit...................................................
Casters, 2" dia.
...........................................0569-286
Door Replacement Kit................................ 5508-084
Rack
Insert..................................................1137-130-03
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
INSTALLATION INSTRUCTIONS
FOR HOLDING CABINET
CMP PART#
0810-029
0852-091
0519-074-K
0861-077
Holding Cabinet
FIGURE 2
TROUBLE-SHOOTING CHART
FAILURE
1. Unit does not heat:
2. Unit will not turn off: 2a. Thermostat turned down.
If cause is none of the above, refer to our list of
authorized service agencies, FL-1400.
Instructions for replacing parts are
included in replacement parts kits.
Insulated
FL-0520-3
Rev. 7 (4/06)
Page 3 of 4
POSSIBLE CAUSE/CHECK
1a. Thermostat turned up.
1b. Switch is "ON".
1c. Cord is plugged into outlet.
1d. Circuit breaker/fuse for
wall outlet
2b. Switch is "OFF"