Bit Name
Bit Number
MERRE
[7]
WAKIE
[6]
ERRIE
[5]
TX2IE
[4]
TX1IE
[3]
TX0IE
[2]
RX1IE
[1]
RX0IE
[0]
¹ –
This is the default value on power-up or reset
2.2.2 CANINTF
The CANINTF register (page 51) holds the flags of all the interrupts that are enabled through the CANINTE register.
If an interrupt flag is set, it must be cleared by the system board to reset the interrupt condition.
Bit Name
Bit Number
MERRF
[7]
WAKIF
[6]
ERRIF
[5]
TX2IF
[4]
TX1IF
[3]
TX0IF
[2]
RX1IF
[1]
RX0IF
[0]
¹ –
This is the default value on power-up or reset
2.2.3 CANSTAT
The CANSTAT register (page 54) provides the status of the CAN controller and the source of the interrupt flag.
Copyright Digilent, Inc. All rights reserved.
Other product and company names mentioned may be trademarks of their respective owners.
CANINTE 0x2B
Bit Description
Message Error Interrupt Enable Bit
Wake-up Interrupt Enable Bit
Error Interrupt Enable Bit
Transmit Buffer 2 Empty Interrupt
Enable Bit
Transmit Buffer 1 Empty Interrupt
Enable Bit
Transmit Buffer 0 Empty Interrupt
Enable Bit
Receive Buffer 1 Full Interrupt
Enable Bit
Receive Buffer 0 Full Interrupt
Enable Bit
CANINTF 0x2C
Bit Description
Message Error Interrupt Flag Bit
Wake-up Interrupt Flag Bit
Error Interrupt Flag Bit
Transmit Buffer 2 Empty Interrupt
Flag Bit
Transmit Buffer 1 Empty Interrupt
Flag Bit
Transmit Buffer 0 Empty Interrupt
Flag Bit
Receive Buffer 1 Full Interrupt Flag
Bit
Receive Buffer 0 Full Interrupt Flag
Bit
Bit Values
Functional Description
1-Interrupt on error during
message reception or
transmission/0-Disabled
1-Interrupt on CAN bus
activity/0-Disabled
1-Interrupt on EFLG error
condition change/0-Disabled
1-Interrupt on TXB2
becoming empty/0-Disabled
1-Interrupt on TXB1
becoming empty/0-Disabled
1-Interrupt on TXB0
becoming empty/0-Disabled
1-Interrupt when message
received in RXB1/0-Disabled
1-Interrupt when message
received in RXB0/0-Disabled
Bit
Functional Description
Values
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
1-Interrupt pending/0-No
interrupt pending
Page 4 of 8