Cres Cor 1000-CH-AL Посібник з монтажу та експлуатації - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Духовка. Cres Cor 1000-CH-AL. Cres Cor 1000-CH-AL 14 сторінок. 1000-ch series radiant ovens

5925 Heisley Road • Mentor, OH 44060-1833
WARNING
IF UNIT GETS TOO HOT OR WON'T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is blown.
PROBLEM
Oven does not heat, or doesn't heat
properly
Timer runs down, but oven does not go
into hold mode.
Heaters will not shut off
Vent fans do not shut off
Vent fans do not operate
(See Note)
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures.
Replacement of electrical components must be done by a qualifi ed electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service
centers.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

MAINTENANCE INSTRUCTIONS

TROUBLE-SHOOTING GUIDE
If hot unit is NOT working, fi rst check the following causes:
POSSIBLE CAUSE
1. Thermostat(s) defective
2. Heater contactor
3. On/Off Switch
*4. Fuses
Timer defective
1. Thermostat defective
2. Contactor defective
1. Vent fan switch defective
2. Control compartment is still hot.
1. Vent fan switch defective
2. Vent fan defective
*3. Fuses
*Fuses are in 6000 Watt units only
3. Switch(es) are turned off.
4. Thermostat(s) are turned off, or are set too low.
FL-2340
Ovens
Rev. 5 (7/08)
Page 7 of 14
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heaters will not shut off"
1. Replace
2. Replace
3. Replace