Display for magnetic band
Count direction
Set out the count direction of the display, range allowed 0 or 1. Factory default 0.
Setting 0, the value on the display increases moving the sensor to the right (sensor as per draw on page 1).
Setting 1, the value on the display increases moving the sensor to the left.
Keys opening mode
This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key
, the digit in the middle stands for key
RESET
The Factory default is 101 or rather with the functions of absolute/relative quote (
(
/
key) activated.
RESET
ENTER
The values allowed are the following:
VALUE
KEY
0
Not open
1
Function
2
Not open
3
Not open
4
Not open
Reset: function of reset of quota, pressing on key
Preset: function of preset of quota, pressing on key
of the one set in parameter Preset. The setting of Preset value appears immediately after parameter
(if chose value 2).
Preset Veloce: the fast setting of the quota on the display, pressing on key
pressing still 2 times
RESET
/
). This function is useful when the quote on the display has often be corrected.
RESET
ENTER
Origin change (quota correction for tool change): with this function 5 different origins (1,2,3,4,5 are
programmable and passes from an origin to the other wit key
change on the display appear two small arrows and the indication of the selected origin happens with the
switching on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on
the right of
, will appear
read in this position of sensor for origin 1, confirm with
to be read for origin 2 in the present position of sensor: set the correct value and confirm with
It will appears
correct value and confirm with
For
and
It means
,
sensor, in 5 different origins.
Function
/
: Enables the pass from absolute to relative value, pressing key
ABS
REL
value to allow a relative shifting. On the display switches on indicator REL to indicate that the current quote is
relative to the zero-point just created. Pressing still key
switches on the indicator ABS.
Conversion mm/inch: Pressing key
indication of inch/mm on the display and a decimal number more then for millimetres. By choosing 5
decimals for millimetres the conversion in inches is not allowed.
Visualization in degrees: Pressing on key
measure in degrees.
Data: 13/01/16
/
ABS
REL
/
is possible to set the value directly (use keys
ENTER
and pressing 2 times
which is the value to be read for origin 3 in the present position of sensor: set the
/
.
RESET
ENTER
to proceed as mentioned above.
,
,
,
converts the measure from millimetre to inches and back with
while the last digit on the left stand for key
KEY
Not open
Conversion mm/inch
Display in degrees
Not open
Not open
/
the quota is zero-set.
RESET
ENTER
/
the quota on the display became the same
RESET
ENTER
/
RESET
ENTER
/
RESET
ENTER
/
. It will appear
RESET
ENTER
are references for the calibration, in a certain position of the
reappears the absolute value and on the display
on the display appears Deg to indicate the visualization of
file: F20_ing.doc
/
key) and reset
ABS
REL
KEY
/
RESET
ENTER
Not open
Reset
Preset
Fast Preset
Change of origin1,2,3,4,5
/
appears Preset and
RESET
ENTER
and confirm with
. Activating the function of origin
has to be set the value to be
which is the value
RESET
zero-set temporary the
F20
/
.