FIAMA EP46NET Посібник - Сторінка 13

Переглянути онлайн або завантажити pdf Посібник для Вимірювальні прилади FIAMA EP46NET. FIAMA EP46NET 13 сторінок. Electronic hollow shaft display with fieldbus

FIAMA EP46NET Посібник
Hollow shaft display with fieldbus
Technical specifications
Power supply
Battery life 6-8 years
Hollow shaft diameter
Max rotation speed
Resolution
Range
Display
Keyboard
Bus output
Bus port connection
Power supply connection
Available functions
Protection degree
Working temperature
Relative humidity
Electromagnetic compatibility
RoHS
Manufacturer
All communications to the manufacturer should be addressed to:
FIAMA s.r.l., Via G. Di Vittorio, 5/A – 43016 San Pancrazio (Parma) - Italy
Tel. (+39) 0521.672.341 – Fax. (+39) 0521.672.537 – e-mail: [email protected] – www.fiama.it
FIAMA srl is not responsible for any damage to persons or things caused by tampering and improper
use and in any cases that are not compatible with the features of the instrument.
08/09/22
10-30 VDC, max 100mA
3,6V 1/2 AA format
EP43NET: Ø14, Ø1/2"
EP46NET: Ø20, Ø3/4", Ø25
1000 RPM
EP43NET: 3200 pulses/revolution
EP46NET: 4000 pulses/revolution
-99999; 99999
high readability LCD with 10mm-high-digits
3 digits for programming and function activation
Profinet, EthernetIP, EtherCAT, PowerLink, IOLink
2 connectors M12x1, D coding
1 connector M12x1, A coding
reset/preset, absolute/incremental value, mm/inches conversion
IP65
0-50°C
35-85%
2014/30/UE
2011/65/UE
EP4NET_1.2_ing.doc
rev: 1.2
EP4-NET