Diginet LEDsmart MMDM/PB Посібник з монтажу - Сторінка 14

Переглянути онлайн або завантажити pdf Посібник з монтажу для Диммер. Diginet LEDsmart MMDM/PB. Diginet LEDsmart MMDM/PB 16 сторінок. Push button dimmer with built in on / off switch and multi-way control

FLICKERING OR FLASHING WHEN OFF OR AT LOW DIMMING LEVELS
Modern LED lighting has revolutionised high brightness low power
lighting.
Unfortunately, some LED loads can have problems with dimmer
compatibility. This can be observed when lamps flicker or flash
when set to low dimming levels or when a MultiMate™ device is
set to the OFF condition.
The MMBP load bypass is wired across the lamp. It will resolve
almost all issues associated with dimming of LED lighting,
including:
-
Lamp glow when turned off;
-
Flickering or pulsing of the lamp when turned off or to low
dimming levels; and
-
Flickering or pulsing of the dimmer LED status indicators.
Solutions for lamp flickering at low dimming levels
Solution 1: Use the setup functions of the dimmer, timer, switch or occupancy sensor to adjust the
MINIMUM dimming level to a higher value. Refer to the product installation guide for details.
Solution 2: Fit a load bypass device – order code MMBP.
Solution 3: In extreme cases, both the MMBP and a raised minimum level may be needed.
Solutions for flickering or pulsing of dimmer LED status indicators.
Solution 1: Fit a load bypass device (MMBP).
Solution 2: Newer model dimmers introduce CLM mode. Use the setup guide for your product and activate
CLM mode.
Solution 3: In extreme cases, both the MMBP and enabling CLM mode may be needed.
Solutions for lamp flickering or flashing when turned OFF
Fit an MMBP load bypass. It is designed for this issue. Similar products are also available from other
manufacturers.
How to install the MMBP load bypass device
The MMBP load bypass device is installed in parallel with the load, across the switched Active and Neutral,
as shown in the diagram below.
Before Load Bypass Installed
Active
Neutral
Caution: Do not wire the MMBP across the dimmer terminals. This will not be effective.
13-14-031D-20-01 – Issue 1
Active
Neutral
N
LAMP
LOAD
October 2020
LEDsmart+ / MultiMate™
After Load Bypass Installed
N
LAMP
LOAD
Troubleshooting Guide
N
L
MMBP
Load
Bypass
Page 2 of 4