DR4018 DIGISWITCH (v1.2)
#
CV Definition
113
Output Configuration 1
Bit
Function
Intensity of the output. Also called dimmer. Where 0 is completely off
and 15 completely on.
0 - 3
Fade in and fade out effect. "0" = no fading "1" = fading active. Fade
speed is controlled by CV111
4
Blink effect. "0" = no blinking "1" = blinking active. Blink rate is con-
trolled by CV112
5
Random effect. "0" = random off "1" = random active. Combined with
bit 4 (fade) the lights start with a flash, after which they slowly fade in.
Note: The intensity value should be max. 14 for this effect to work.
6
Pulse length. is set via CV 121 through 128, when combined with bit 5
the output blinks, but with inverted phase
7
114
Output Configuration 2 (For configuration bits see CV113)
115
Output Configuration 3 (For configuration bits see CV113)
116
Output Configuration 4 (For configuration bits see CV113)
117
Output Configuration 5 (For configuration bits see CV113)
118
Output Configuration 6 (For configuration bits see CV113)
119
Output Configuration 7 (For configuration bits see CV113)
120
Output Configuration 8 (For configuration bits see CV113)
121
Output Configuration 9 (For configuration bits see CV113)
122
Output Configuration 10 (For configuration bits see CV113)
123
Output Configuration 11 (For configuration bits see CV113)
124
Output Configuration 12 (For configuration bits see CV113)
125
Output Configuration 13 (For configuration bits see CV113)
126
Output Configuration 14 (For configuration bits see CV113)
127
Output Configuration 15 (For configuration bits see CV113)
128
Output Configuration 16 (For configuration bits see CV113)
131
Signal 1, configuration OUT 1 - 4
If these CVs contain a value equal to 0 all outputs will switch according to the signal rules. The other CVs that nor-
mally control the outputs will be deactivated.
Preset Function
0
No Signal
1
Dutch (railways)
2
DB_HP (German main signal)
3
DB_VRHP (German front and main signal)
4
DB_VR (German front signal)
5
NMBS (Belgium railways)
132
Signal 2, configuration OUT 5 - 8
133
Signal 3, configuration OUT 9 - 12
134
Signal 4, configuration OUT 13 - 16
www.digirails.com
Default
Value
15
0-15
0
16
0
32
0
64
0
128
Range
Value
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-255
143
0-5
0
0-5
0
0-5
0
0-5
0
Page 6