Remove Touchpanel Nose
NOTE: Steps 12 through 20 only need to be completed if the internal base plate is painted
and replacing the panel is not a valid option. Please contact customer support for additional
information. If the internal base plate has no paint, continue with step 21.
WARNING: Bix Stripper is an irritant to skin, eyes, and respiratory tract. Skin and eye
protection required. Avoid repeated or prolonged contact. Good ventilation is required. If
misting or vapors occur, use NIOSH approved organic vapor air purifying respirator. Observe
all warnings and cautions supplied by the manufacturer.
CAUTION: Do not allow Bix stripper to come into contact with internal components,
cabling, or other plastic material of the touchpanel. Doing so can damage the material and
may prevent the touchpanel from operating normally.
Field Service Guide - DOC. 5956
ONLY IF NECESSARY.
12. Remove two front rubber feet from the touchpanel base plate.
13. Slightly lift the panel from the bench exposing the external side of the base plate.
To avoid stripper material from damaging external side of the base plate, place
strips of masking tape over the two holes that housed the rubber feet and the two
smaller screw holes in between them.
14. Use the nylon brush and dab a generous coat of the Bix Stripper onto an interior
area of the touchpanel base plate as defined in the diagram on the next page.
REMOVE FEET