FIBARO FGMS-001 Посібник з експлуатації - Сторінка 14
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Аксесуари FIBARO FGMS-001. FIBARO FGMS-001 20 сторінок. Motion sensor
Також для FIBARO FGMS-001: Посібник з експлуатації (2 сторінок), Посібник з експлуатації (11 сторінок)
14
i
NOTE
Device operating in
Security Mode does
not send frames in
broadcast mode. In
this case leave the de-
fault values of param-
eters 28 and 29.
ADvAnCED PARAMETERS
20. Tamper - sensitivity
This parameter determines the change in force acting on the device,
that will result in reporting tamper alarm - g-force acceleration.
Available settings: 0 - tamper inactive
Default setting:
22. Tamper - alarm cancellation delay
Time period after which a tamper alarm will be cancelled in the main
controller and associated devices.
Any tampering detected during this period will not extend the delay.
Available settings: 1-32767 (in seconds)
Default setting:
24. Tamper - operating modes
This parameter determines function of the tamper and sent reports.
It is an advanced feature serving much more functions than just de-
tection of tampering.
Available settings: 0 - tamper only
Default setting:
25. Tamper - alarm cancellation
This parameter allows to disable cancellation of the tamper alarm.
Available settings: 0 - do not send tamper cancellation report
Default setting:
28. Tamper - broadcast mode
The parameter determines whether the tamper alarm frame will or
will not be sent in broadcast mode. Alarm frames sent in broadcast
mode can be received by all of the devices within range (if they ac-
cept such frames), but not repeated by them.
Available settings: 0 - tamper alarm sent to 3rd association group
Default setting:
29. Tamper - backward compatible broadcast mode
The parameter determines whether the backward compatible tam-
per alarm frame will or will not be sent in broadcast mode. Alarm
frames sent in broadcast mode can be received by all of the devices
within range (if they accept such frames), but not repeated by them.
1-121 - (0.08-2g; every 0.016g)
20 (0.4g)
Parameter size:
30 (30s)
Parameter size:
1 - tamper and earthquake detector
2 - tamper and orientation in space
0
Parameter size:
1 - send tamper cancellation report
1
Parameter size:
1 - tamper alarm sent in broadcast mode
0
Parameter size:
1 [byte]
2 [bytes]
1 [byte]
1 [byte]
1 [byte]