I
On factory default the device does not belong to any Z-Wave network. The device needs
to join an existing wireless network to communicate with the devices of this network. This process is called
Inclusion. Devices can also leave a network. This process is called Exclusion. Both processes are initiated
by the primary controller of the Z-Wave network. This controller will be turned into exclusion respective
inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion
or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or
leave the network. Leaving the network - i.e. being excluded - sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network.
Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to
be reset first.
To include the device into the network, turn the controller into the inclusion mode and then triple click the B-
button. Further you can use the auto-inclusion mode by setting the controller into the inclusion mode and
then connect the constant current voltage supply. Auto-inclusion only works in constant current mode.
Operating the device
SMOKE DETECTION
Fibaro Smoke Sensor responds to physical presence of smoke. Smoke presence is required for the device
to react. Fibaro Smoke Sensor performs a self test each 5 seconds and checks for smoke presence. Having
detected smoke presence, the sensor checks 3 more times, at 1 second interval, whether the smoke is
actually present. Once the smoke presence is confirmed, Fibaro Smoke Sensor triggers an alarm.
Smoke alarm is signaled by sending an appropriate alarm frame to devices and the Z-Wave controller,
opening NC contact, and also by a constant sound signal and LED diode blinking red. Once the smoke
alarm has ceased, the sensor checks 3 times, at 1 second interval, whether the smoke has actually
disappeared before getting back to normal operation, i.e. performing a self test each 5 seconds and
checking for smoke presence.
There are 3 sensitivity levels of the optical smoke detector used in Fibaro Smoke Sensor. By default, the
detector is set to the middle sensitivity level. Sensitivity level depends on the parameter 82 settings.
DETECTING FIRE THROUGH TEMPERATURE ALARM
Apart from detecting smoke presence, Fibaro Smoke Sensor can detect fire by recording a rapid
temperature rise. Temperature alarm threshold is user defined (parameter 81). Temperature alarm is
signaled by the LED signaling diode blinking red and an intermittent sound signal.
Wakeup Intervals - how to communicate with the device?
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7