FIBER FOX Mini 6SI Посібник користувача - Сторінка 13
Переглянути онлайн або завантажити pdf Посібник користувача для Мережеве обладнання FIBER FOX Mini 6SI. FIBER FOX Mini 6SI 16 сторінок.
Appendix I
Splice loss increase : Reason and solution.
Symptom
Name
Core Axial
Dust on v-groove or fiber
Offset
clamp chip
Dust on v-groove or fiber
clamp chip
Core Angle
Bad fiber end-face quality
Dust on v-groove of fiber
Core Step
clamp chip
Bad fiber end-face quality
Core Curve
Pre-fuse power too low or
pre-fuse time too short
MFD
Arc power too low
Mismatch
Bad fiber end-face quality
Combution
Dust still present after
cleaning fiber of cleaning
arc
Bad fiber end-face quality
Bubbles
Pre-fuse power too low or
pre-fuse time too short
Fiber stuffing too small
Separation
Pre-fuse power too high of
pre-fuse time too long
Reason
Solution
Clean v-groove and fiber
clamp chip
Clean v-groove and fiber
clamp chip
Check if fiber cleaver is well
conditioned
Clean v-groove and fiber
clamp chip
Check if fiber cleaver is well
conditioned
INcrease [Pre-fuse power]
and/or [Pre-fuse time]
Increase [Arc power]
Check the cleaver
Clean fiber throughly or in-
crease [Cleaning arc time]
Check if fiber cleaver is well
conditioned
Pre-fuse power too low or
pre-fuse time too short
Perform [Motor calibration]
Decrease [Pre-fuse power]
and/or [Pre-fuse time]
- 24 -
Fat
Fiber stuffing too much
Arc power not adequate
Thin
Some arc parameters not
adequate
Some arc parameters not
Line
adequate
Note : A vertical line sometimes appears at the splice point when MM fibers, or dissimilar fibers (different diam-
eters) are spliced. This does not affect splice quality, such as splice loss or tensile strength.
Decrease [Overlap] and
perform [Motor clibration]
Perform [Arc calibration]
Adjust [Prefuse power],
[Pre-fuse time] or [Overlap]
Adjust [Prefuse power],
[Pre-fuse time] or [Overlap]
- 25 -