Sharp Carousel R-1200 Посібник з експлуатації - Сторінка 16
Переглянути онлайн або завантажити pdf Посібник з експлуатації для Мікрохвильова піч Sharp Carousel R-1200. Sharp Carousel R-1200 40 сторінок. Over the counter microwave oven
Також для Sharp Carousel R-1200: Брошура та технічні характеристики (8 сторінок), Посібник з експлуатації та інструкція з монтажу (32 сторінок)
R-1200
R-1201
PROCEDURE
LETTER
When the monitor switch actuator is pushed by a screw driver through the lower latch hole on the front
plate of the oven cavity with the door opened (in this condition the plunger of the monitor switch is
pushed in), the meter should indicate an open circuit. If improper operation is indicated, the switch
may be defective. After testing the monitor switch, reconnect the wire lead to the monitor switch
(COM) terminal and check the
continuity of the monitor circuit.
5. Reconnect all leads removed from
components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord
after the outer case is installed.
8. Run the oven and check all
functions.
I
BLOWN MONITOR FUSE TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the monitor fuse is blown when the door is opened, check the secondary interlock relay, primary
interlock switch and monitor switch according to the "TEST PROCEDURE" for those switches before
replacing the blown monitor fuse.
CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE SECONDARY INTER-
If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must
be replaced with "monitor fuse and monitor switch assembly" part number FFS-BA016/KiT, even if
the monitor switch operates normally. The monitor fuse and monitor switch assembly is comprised
of a 20 ampere fuse and switch.
5. Reconnect all leads removed from components during testing.
6. Re-install the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
J
TOUCH CONTROL PANEL ASSEMBLY TEST
The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter
and ohmmeter.
In this service manual, the touch control panel assembly is divided into two units, Control Unit and Key
Unit, and also the Control Unit is divided into two units, LSI Unit and Power Unit, and troubleshooting by
unit replacement is described according to the symptoms indicated.
Before testing,
1) Disconnect the power supply cord, and then remove outer case. Refer to procedure of "
REMOVAL OF OVEN FROM WALL " and " OUTER CASE REMOVAL ".
2) Open the door and block it open.
3) To discharge high voltage capacitor, wait for 60 seconds.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using insulation
tape.
1. Key Unit.
NOTE ;
1) Check key unit ribbon connection before replacement.
2) Re-install the outer case (cabinet).
3) Reconnect the power supply cord after the outer case is installed.
4) Run the oven and check all functions.
TEST PROCEDURES
LOCK RELAY, PRIMARY INTERLOCK SWITCH, DOOR SENSING SWITCH AND MONI-
TOR SWITCH FOR PROPER OPERATION.
COMPONENT TEST
Red
White/ White
Screw Driver
Primary
Interlock Switch
14
Ohmmeter
Monitor Switch