R - 5 3 0 E K
R- 530EW
PROCEDURE
LETTER
Steaks, chops or fish
(5) If improper operation is indicated, the control unit is probably defective and should be checked.
M
FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on
the PWB, this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
STEPS
5) Make a visual inspection of the varistor.
Check for burn damage and examine the
transformer with a tester for the presence
of layer short-circuit (check the primary
coil resistance which is approximately
210
is detected, replace the defective parts.
6) Reconnect all leads removed from components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator does not light up after above check and
repairs are finished.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
6) After that procedure, reconnect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS
8) Disconnect the power supply cord, and then remove outer case.
9) Open the door and block it open.
TEST PROCEDURES
MENU
1ST STAGE
LEVEL
0.5lb
70%
OCCURRENCE
1
Only pattern at "a" is broken.
2
Pattern at "a" and "b" are broken.
15%). If any abnormal condition
OCCURRENCE
The rated AC voltage is not present between
1
Pin No. 1 of the 2-pin connector (A) and the
common terminal of the relay RY1.
The rated AC voltage is present at primary
2
side of low voltage transformer.
COMPONENT TEST
2ND STAGE
TIME
LEVEL
30sec.
40%
CAUSE OR CORRECTION
*Insert jumper wire J1 and solder.
*Insert the coil RCILF2003YAZZ between "c" and "d".
CN - A
d
b
a
CAUSE OR CORRECTION
Check supply voltage and oven power cord.
Low voltage transformer or secondary circuit defective.
Check and repair.
18
TIME
15sec.
(J1)
c