Sharp 20N-S100S Посібник з експлуатації - Сторінка 10
Переглянути онлайн або завантажити pdf Посібник з експлуатації для ТЕЛЕБАЧЕННЯ Sharp 20N-S100S. Sharp 20N-S100S 29 сторінок.
20N-S100S
CN20S10
FEATURE
SERVICE
ADJUST ITEM
POSITION
M01
MS LEVEL
M02
MTS-VCO
M03
FILTER
M04
LOW SEPARATION
M05
HIGH SEPARATION
Note: Refer to the SERVICE ADJUSTMENT for each corresponding values.
Holding down both the Vol-up/Ch-down buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
PART REPLACED
NECESSARY
IC2001
IC201
IC2101
CRT
DATA
INITIAL VALUE
RANGE
00-0F
00-3F
00-3F
00-3F
00-3F
Table - D
ADJUSTMENT
UNNECESSARY
X
X
X
X
Table - E
ADJUSTMENT CONTENTS
0A
20
1C
20
1B
NOTES
Data is stored in IC2101.
The adjustment is needed to compensate for characteristics
of parts including IC201.
Holding down both the Vol-up/Ch-down buttons on the TV
set in the service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
Adjust items related to picture tube only.
10