Digital Equipment Prioris XL 5166 Посібник з монтажу - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник з монтажу для Сервер Digital Equipment Prioris XL 5166. Digital Equipment Prioris XL 5166 17 сторінок. Cpu powergrade kit

Digital Equipment Prioris XL 5166 Посібник з монтажу
Prioris XL and XLDP Server Powergrade Kit

Reset Jumpers on the Main Logic Board

1. As described previously, power down the server.
2. Make sure that the following jumpers, shown in Figure 1, are set to disabled
to prevent any unauthorized update to your BIOS:
J41
BIOS upgrade
J50
Boot block update
Powergrade Installation
Remove the CPU Module
1. Place the antistatic wrist strap on your wrist and connect the grounding
clip to a non-painted metal surface of the computer's chassis.
2. Using a Phillips screwdriver, unscrew and remove the CPU module
retaining bracket (Figure 2).
3. Grasping both ends of the CPU module, carefully remove it from the main
logic board and place it on an antistatic surface.
6
Disabled (Off)
Move the jumper back to the default position
shown in Figure 1 (pin 1 to pin 2).