Using the Optional Large Capacity Input Tray

1.5 Service Notes

1.5 Service Notes
The OLCIT is similar in operation and service to the 1000 sheet LCIT. The
OLCIT has an internal controller that operates the elevator tray motor and
signals the PrintServer duplexer-table controller.
The 1000 sheet LCIT has no internal controller and its motor and other functions
are controlled directly by the duplexer-table controller.
It is this difference that accounts for the small changes in response to the
PrintServer 32 diagnostic service procedures.
Use the diagnostic procedures for the LCIT (in the PrintServer 32 service
manual) to diagnose the OLCIT. Table 1–4 shows the failure modes and actions
for the user and service personnel. Refer to the PrintServer 32 Service Manual
for service procedures.
Table 1–4 OLCIT Diagnostics
PrintServer
Control
Panel
Problem
Message
Elevator does
Error 41
not move up or
down
Small white
Close paper
OLCIT
tray door
connector not
engaged
Large blue
Error 52
OLCIT
connector not
engaged
Wrong printing
None
position on
paper or image
position
Printing is
None
skewed on the
paper
If you have an LCIT (1000 sheet feeder), verify that the OLCIT (3000
sheet feeder) is the problem by installing the LCIT. If the LCIT works,
then replace the OLCIT.
1–12 Using the Optional Large Capacity Input Tray
User
OLCIT Panel
Actions
Elevator green
Call service
LED blinking
Red LED on
Verify connection; if
error persists, call
service
No power
Verify connection; if
error persists, call
service
None
Set paper size rotary
knob to correct size. You
must change the Paper
Size setting when the
cover is open.
None
Adjust paper guides on
OLCIT to paper edges.
Verify that Paper Size
selection knob setting
corresponds to the Paper
Adjustment lever. You
must change the Paper
Size setting when the
cover is open.
Note
Service
Actions
Replace OLCIT
Verify that harness is
OK. If no good, replace
OLCIT
Verify that harness is
OK. If no good, replace
OLCIT
None
None