Cleaning the filters in the water inlet
The filters in the water inlet must be cleaned
when, with the tap turned on, no water or only a
very small amount enters the appliance.
The filters are located in the hose connection
which joins the water inlet pipe to the mains tap,
as well as in the connection of the solenoid valve
at the rear of the appliance.
Procedure
m Firstly empty the water pressure from the
inlet pipe:
1. Turn off the tap.
2. Set the programme selector to any wash
programme (except
b
(I)).
M
3. Press the «
» button. Let it run for at
least 1 minute.
4. Turn the programme selector to «
m Unscrew the inlet pipe from the tap. Rinse
the filter under running water.
m Screw the pipe to the tap again.
m Remove the water inlet pipe from its con
nection at the back of the machine.
m Remove the filter by using some flat-nose
pliers; clean it and put it back in its position.
m Attach the pipe to its coupling.
m Turn on the tap and check that there are no
water leaks.
m Turn off the tap.
Technical data
Width
59.5 cm
Height
85.0 cm
Depth
56.0 cm
Weight
approx. 70 kg
14 en
All manuals and user guides at all-guides.com
spin B
empty
(H) /
stop
».
Frost protection
Drain the water from the pump:
See «Cleaning the drainage pump».
Drain the water from the inlet pipe:
m Turn off the tap.
m Disconnect the inlet pipe from the tap. Put
the end of the pipe in a receptacle.
m Select any wash programme (except
B
empty b
(H) /
onds. The water in the pipe is drained.
m Reattach the pipe to the closed tap.
Drum capacity
Mains voltage
Fuse
Water supply pressure
spin
(I)). during 40 sec
according to
specifications
plate