ActronAir Cascade 2 URC-140CS Посібник користувача - Сторінка 6
Переглянути онлайн або завантажити pdf Посібник користувача для Кондиціонери ActronAir Cascade 2 URC-140CS. ActronAir Cascade 2 URC-140CS 16 сторінок. Four way cassette
Owner's Manual
Auto-Restart
The system has an auto restart function. If a power failure occurs, the system will immediately stop. When power returns,
the unit will restart automatically in its last programmed setting once power is resotered.
Louvre Angle Memory Function
When the unit restarts after a power failure, the angle of the horizontal louvres will automatically return to the previous
position. The angle of the horizontal louvre should not be set to small opening (or near close possition) as condensation
may form and drip from the machine.
NOTE
Lightning or any electronic interference nearby may cause the unit to malfunction. If this happens, reset the power mains
(isolator). Press the ON/OFF button on the wired controller to restart operation.
Optimal Operation
To achieve optimal performance, please note the following:
• Adjust the direction of the air flow so that it is not blowing directly onto people.
• Adjust the temperature to achieve the highest possible level of comfort. DO NOT adjust the unit to excessive
temperature levels.
• While cooling, close the blinds or curtains to avoid direct sunlight.
• Doors and windows should be kept closed to keep cool or warm air in the room.
• Set an ON/OFF TIMER and use SLEEP/ECONOMY feature.
• Do not place any object near the air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the
air conditioner may stop running.
• When a remote control is used, remove the batteries if you don't plan to use the unit for a long time.
• Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
06. Care and Maintenance
NOTES
Apart from Cleaning the Air Filter, all other general maintenance and care of systems should be undertaken by a licensed
technician.
Service, maintenance, repairs and decommissioning of this unit must be performed by a licensed HVAC technician; qualified
to handle R-32 refrigerant.
Maintenance Procedures
This section describes the procedures that must be performed as a part of normal maintenance program. Regular
servicing of equipment by a licensed technician is highly recommended. Regular servicing of your unit helps in
maintaining its optimum performance and reliability. The checklist and service periods provided in this manual are
guides only, as some sites may require more frequent servicing. Always disconnect electrical power to the unit before
performing these procedures. It is always a safe practice to observe all safety warnings and cautions when conducting
maintenance tasks.
WARNING
Hazardous Voltage !
Always make sure that all power supply, including remote controls, are disconnected before performing maintenance.
Observe proper LOCK-OUT/TAG-OUT procedures to ensure that power cannot be inadvertently energised. Failure to
disconnect power before maintenance procedures can result in serious injury and/or death.
6
Owner's Manual - Cascade Series 2
Doc. No. 9590-4016 Ver. 2 220616
Four-Way Cassette