Cisco - Hardware Troubleshooting for Cisco 12000 Series Internet Router Line Card Failures
Line card has passed Field Diagnostic test
PASS
DIAG
Line card is executing Field Diagnostic software
TEST
FABL
Line card is launching "Fabric Downloader"
DNLD
FABL
Line card is waiting to load "Fabric Downloader"
WAIT
IN RSET
Line card is resetting
Line card is downloading Cisco IOS software through
IOS DNLD
the switch fabric
IOS RUN
Line card is now enabled
Line card has finished loading and is now running
IOS UP
Cisco IOS software
MBUS
Line card is downloading Maintenance Bus (MBUS)
DNLD
agent
MEM INIT Line card is trying to size memory
PWR OFF
Line card is powered off
If the line card status is anything other than "IOS RUN", or the GRP is neither the active Master/Primary nor the
Slave/Secondary, this means that there is a problem and the card has not fully loaded correctly. Before you replace the
card, Cisco recommends that you try these steps to fix the issue:
1. Reload the microcode through the microcode reload <slot> global configuration command.
2. Reload the card through the hw-module slot <slot> reload command. This causes the line card to reset and re-
download the Maintenance Bus (MBUS) and Fabric Downloader software modules before it attempts to re-
download the line card Cisco IOS software.
3. Reset the line card manually. This can rule out any problems that are caused by a bad connection to the MBUS
or switching fabric.