OPERATION
Your ACE Industial Producls machine is designed as a
source caolure device, i.e., il is inlended to eliminale
smoke and partrculale at theit point ol origin Keeping this
jn mind, the machine should be operated in the following
Re-read the section on Safety Wamings & Caulions
before prcceeding any turther.
1. Place lhe machine on a flat, level surface Pick a
location that will allo"v unrestricted flow of the exhausl
air to lh€ atmosphere.
2. For units wilh wheels or casters, lock lhe wheels or
block lhe wheels.
3. Place lhe coltection nozzle as close to the wolft as
practical without intedering wilh the operator. Sec|lrc
the nozzle if necessary.
lJsinothe ON/OFF switch, tum lhe machine on
Should the motor not start, or should the machine
make unusualnoises. immediately lum he machine
off and seek trained maintenance personnel Do nol
conlinue to use the unit.
lJDon completion ol the speofic manufacturing or
w;bino ooeralon, tum lhe machine ofl Contnuous
runnin; oi|he unit will r€duce the litu ol lhe frltet and
the mdtor brushes as well as increase utility cosl
When lhe "clogged' filte. lighl indicates ihal the filter
is dogged, tlm lhe machine off and remove power
cord ftom its Power source
See the section on installation and use the reverse
process to remove lhe dirty lillers Re_inslall the new
iilter and reconnect the machine to its power source'
MAINTENANCE & REPLACEMENT PARTS
FILTERS:
As oreviouslv stated in lhe Theory of Operation' seclion
oitiris r"nuit, ttte "Aogged'lilter indicator light willlight
whenever the dfierental pressure across the nller
incticates lhat lhe flter-rs ctogged. \ryhen opening the unn'
there are no vacuum hoses to disconnect since lhe
o.essure sensinq is acaomplished by measunng al the
inletand insid€the suclion chamber' The drffetential
pressure ttip poinl is preset and is not field adjuslable-
\ r'hen the nlter gets dirty, il needs to be €placed wilh a
new one or the-fitter can becleaned Toclean take lhe
flter out of lhe unil. Hotd the flter 2 to 3 inches above a
concrete foor. Gentiv clrop the fller. Iotate and repeat unttl
mosl of the dirt falls orn of lhe liller or lhe fher can be
vacuumed with a Dortable sh vac (lf needed' order 8G
201MD). To re_assemble, use reverse process fo remove
flter and s\N€ep up dirt lhat is on the ioor'