4. WIRING INSTRUCTIONS
HNS220TD
Neutral
Rem
Active
Load
4.1 REMOTE SWITCH (REM)
• The remote switch must be a normally open 240V momentary switch. Eg. HPM EM870K or CLIPSAL 681M20P.
• Remote wiring should not exceed 50m.
• Holding the remote switch for over 2 seconds will cause the HNS220TD to restart the timer.
5. OPERATING INSTRUCTIONS
ELECTRICAL SAFETY WARNING: Isolate the HNS220TD from the mains power supply before
setting the timer.
The HNS220TD is an Advanced Wall Timer which allows flexible configurable operation. The LED can be
configurable to be either ON or OFF during timer operation. The power to the load can be either ON or OFF
during timer operation.
With a Quick Tap of the button the LED will change indication, depending on LED switch setting and the power
to the load will either switch ON or OFF.
When the timer is in operation, the LED will blink every 5 seconds. During the last 10 seconds of operation the
LED will flash indicating imminent time out.
If there is a sustained 2 seconds press of the button the timer will restart. At any time when the timer is running
a Quick Tap will turn the timer OFF.
The HNS220TD is configured by adjusting the 8 DIP switches inside the unit to the settings required.
5.1 LOAD OUTPUT (POWER ON/ POWER OFF) SWITCH
The HNS220TD can be set so that the power is ON (Normally Open - NO) when the timer is running or set to
OFF (Normally Closed -NC) when the timer is running by setting the Load Output switch.
Load Output Switch
Normally Open (NO)
Normally Closed (NC)
5.2 LED INDICATOR SWITCH
The sense of the HNS220TD LED Indicator can be set to ON or OFF in timer mode based on the table below.
LED Indicator Switch
ON
OFF
Customer Care Australia P: 133 122 F: 1300 303 310 E: [email protected] W:cabac.com.au
A: Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 0800 966 969 F: 0088 6969 E: [email protected] W: cabac.co.nz
ADVANCED WALL TIMER SWITCH MANUAL
Remote
Switch(es)
LOAD
IND
TIMER
OUTPUT
LED
RANGE
NO
ON
R1
R2
NC
OFF
OFF
OFF
Power ON during timer operation (Relay contact closed)
Power OFF during timer operation (Relay contact open)
Indicator ON when power ON. Indicator OFF when power OFF
Indicator OFF when power ON. Indicator ON when power OFF
Neutral
Load
Active
TIMER
SETTINGS
8
4
2
1
OFF
OFF
OFF
OFF
Operating Mode
LED Indicator Mode
CP13944 Rev 1, 19 MARCH, 2014