CFG File Modification
Hide Central Router Name
Typically, when there is a single ISDN connection, it is not necessary to enter a central router name
parameter. The prompt for this parameter can be hidden from the end user. The flag syntax is as follows:
[PPPSettings]
HideCentralRouternameISP=
HideCentralRouternameRCN=
If the flag value is set to 0 or blank, the central router name is hidden.
If the flag value is set to 1, the central router name is shown.
The flag ISP extension refers to Internet service provider (ISP). The flag RCN extension
Note
refers to remote corporate network (RCN).
Erase the Router Configuration
You can use this flag to force the router to reset to the factory default configuration. The flag syntax is
as follows:
[Setup Type]
SetRouterToDefaultConfig=
If the flag value is set to 1, the router is write-erased and rebooted without prompting the end user.
If the flag value is set to 0 or blank, after a connection to the router is established, Setup prompts the
user to append or erase the existing configuration.
Advice of Charge
Advice-Of-Charge (AOC) time-outs for the user connected to the NET3 switches is supported and
controlled using the flags SetAOCTimeout, which determines AOC timeout in seconds, and
AOCShortHoldTimeout, which determines the minimum idle time before the line is dropped. The
default is 120 seconds.
The flag syntax is as follows:
[ISDNSettings]
IdleTimeoutISP=
IdleTimeoutRCN=
SetAOCTimeout=
AOCShortHoldTimeout=
If the IdleTimeoutISP flag is set to 1, the router disconnects from the dialer when there in no traffic to
the ISP.
If the IdleTimeoutRCN flag is set to 1, the router disconnects from the dialer when there in no traffic
to the remote corporate network.
If the value of the SetAOCTimeout flag is set to 1, the dialer ISDN short-hold value time command
(where time is the number of seconds) is placed in the dialer map-class with a value equal to the
AOCShortHoldTimeout flag.
Cisco 800 Fast Step Software Design Guide
2-4
Chapter 2
CFG File Development
OL-10373-02