Ace FMC-200-HYD-310 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Водяний насос Ace FMC-200-HYD-310. Ace FMC-200-HYD-310 12 сторінок. Hydraulic motor driven centrifugal pumps
PLUMBING DIAGRAM
A = 10 x hose diameter
HYDRAULIC MOTOR FEATURES
Coasting Check - This internal feature is standard for all Ace hydraulic motors. It protects the
motor seal from pressure spikes created by the flywheel effect of the impeller when the pump is
turned off.
Needle Valve - The valve allows for bypass of excess hydraulic fluid on open center hydraulic
systems. The valve has a threaded needle with a slotted end and lock nut. The needle on 300A
motors is located under a hex cap with no lock nut.
Reverse Flow Check - The check valve prevents damage by not allowing the pump to run backwards.
The valve is an external fitting on the 200N series motors and internal on 300 series models.
Consult these Ace Product Updates for more information:
Update 1 - Hydraulic Seals
Update 12 - Seal Support Spacer
Update 14 - 200N Series Motors
Update 15 - 300A Series Motors
Jet Agitator
Anti-Vortex
Tank Fitting
Tank Valve
Pressure
Gauge
"Suggested for MAX Series"
Agitation
Pressure Gauge
Agitation Valve
Line
Strainer
Shut-off
Valve
Hydraulic Hose Connections:
2
Pressure Spike Valve
Boom Valves
Control Valve
Flow Meter
200 Series - 1/2" NPT
300 Series - 1/2" NPT