Argo CLIMIA CMK 4000 WiFi Інструкція з експлуатації Посібник з експлуатації - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Кондиціонер Argo CLIMIA CMK 4000 WiFi. Argo CLIMIA CMK 4000 WiFi 20 сторінок. Room air conditioner with remote condenser

CLIMIA

02 - INSTALLATION LOCATION

WARNING
• Do not install the air conditioner where excessively high heat-generating objects are placed.
• Do not install the air conditioner where the atmosphere is extremely damp or humid (e.g. greenhouse or laundry) it could be
wetted by drops of water (i.e. in laundries).
AVOID:
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly
onto it or in sulphurous air near a spa.
Make sure that there are no obstacles around the indoor unit affecting the free circulation of air. Do not block the air intake and
outlet of the unit with curtains or other.Never put objects on the top of the unit.

03 - ELECTRICAL REQUIREMENTS

Before using the appliance
• Check that the power supply at the location where the air conditioner is going to be used is 220/240 volt, single phase.
• For your safety care check periodically the conditions of the electric supply cable; the electrical connection of the unit is Y type
with cable prepared in a special way; in case you should notice any damage due to usage, call the nearest After Sale Service to
get the cable replaced.
• Before connecting the air conditioner to a power socket, make sure that the socket is provided with an earth connection.
• Verify that the available power supply is sufficient for running other electrical domestic appliances in use simultaneously from
the same supply. See the data plate on the unit showing the max. absorbed powers.
• Install a double-pole switch, protected fuses of the delayed type, upstream the electricity wall socket 10A.
• Make sure that circuit breakers, fuses, etc. are of sufficient capacity to handle start - up current (normally for no longer than a
second).
• All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.
WARNING!
The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3 minutes
from a previous stop.
NOTE
This air conditioner is equipped with cooling, drying and fan functions. Details on these functions are provided here following;
refer on these descriptions when using the air conditioner.
OPERATING LIMITS
COOLING
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
DECLARATION OF CONFORMITY
This product is marked with the CE mark because it conforms to the following directives:
– Low Voltage Directive 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 +
A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
– Electromagnetic compatibility 2004/108/CE, 92/31 EEC and 93/68 EEC. (Default: EN55014-1(2006) + A1(2009) + A2(2011), EN 55014-2 (1997)
+ A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009), EN 61000-3-3 (2008)
– RoHS2 n.2011/65/EU.
– Regulation (EU) no. 206/2012, of March 6, 2012, on the specifications for ecodesign of air conditioners and fans.
– Regulation (EU) no. 626/2011, of May 4th, 2011, on the labeling of energy consumption of air conditioning systems.
In the event of incorrect use of the device and/or non-observance of even just parts of the operating manual and the installation instructions
this declaration becomes invalid.
Argoclima S.p.A.
Via Alfeno Varo 35, 25020 Alfianello (BS)
2
• Do not install this air conditioner where there are fumes or flammable gases, or in an extremely
humid space such as a green house.
OUTDOOR TEMPERATURE
ROOM TEMPERATURE
OUTDOOR TEMPERATURE
ROOM TEMPERATURE
46°C D.B.
32°C D.B./23°C W.B.
19°C D.B.
19°C D.B./14°C W.B.