Overview
Figure 7: Firepower 4100 Rear Panel
1
3
5
7
9
The power switch is located to the left of power supply module 1 on the rear of the chassis. It is a toggle
switch that controls power to the system. If the power switch is in standby position, only the 3.3-V standby
power is enabled from the power supply module and the 12-V main power is OFF. When the switch is in the
ON position, the 12-V main power is turned on and the system boots.
You can shut down the chassis in one of two ways:
• Perform a graceful shutdown using the shutdown commands (see the
Caution
• Toggle the power switch to the OFF position. The power LED changes from solid green to off.
Note

Network Modules

The Firepower 4100 contains two network module slots that provide optical or electrical network interfaces.
Network modules are optional, removable I/O modules that provide either additional ports or different interface
types (1/10/40 Gb). The Firepower network modules plug into the chassis on the front panel.
Power on/off switch
Power supply module 2
Fan module 2
Fan module 4
Fan module 6
for the procedure). This may take several minutes to complete. Then toggle the power switch to the OFF
position. The power LED changes from solid green to off immediately.
If you move the power switch to the OFF position before the shutdown
command sequence is complete or if you remove the system power cords
before the graceful shutdown is complete, disk corruption can occur.
After removing power from the chassis either by moving the power switch to OFF or unplugging the
power cord, wait at least 10 seconds before turning power back ON.
2
Power supply module 1
Fan module 1
4
6
Fan module 3
8
Fan module 5
10
Location for the two-post grounding lug
The two-post grounding lug is
Note
included in the accessory kit.
FXOS CLI Configuration Guide
Network Modules
Overview
11