Option
Switch #
Opsw 43
Opsw 44
Opsw 45
Opsw 46
Opsw 47
Opsw 48
c=do not allow selective transponding disabling by Opsw 51-58
Opsw 50
Opsw 51
Opsw 52
Opsw 53
Opsw 54
Opsw 55
Opsw 56
Opsw 57
Opsw 58
9.0 Auto-Reversing
The power management timing used by the BXP88 may not be compatible with
some auto-reverser control items connected upstream on the RA and RB input
connections. A downstream auto-reverser on a DS will show that Detection Sec-
tion as occupied at all times, but Transponding will work. An upstream auto-re-
verser will reverse all of a BXP88's detection sections tracks, so these 8 detection
sections can only be used within the same single reverse area or power district.
© 2017 Digitrax, Inc.
c=disable occupancy reporting for Detection Section 3
t=enable occupancy reporting for Detections Section 3
c=disable occupancy reporting for Detection Section 4
t=enable occupancy reporting for Detections Section 4
c=disable occupancy reporting for Detection Section 5
t=enable occupancy reporting for Detections Section 5
c=disable occupancy reporting for Detection Section 6
t=enable occupancy reporting for Detections Section 6
c=disable occupancy reporting for Detection Section 7
t=enable occupancy reporting for Detections Section 7
c=disable occupancy reporting for Detection Section 8
t=enable occupancy reporting for Detections Section 8
t=allow selective transponding disabling by Opsw 51-58
c=disable transponding reporting for Detection Section 1
t=enable transponding reporting for Detections Section 1
c=disable transponding reporting for Detection Section 2
t=enable transponding reporting for Detections Section 2
c=disable transponding reporting for Detection Section 3
t=enable transponding reporting for Detections Section 3
c=disable transponding reporting for Detection Section 4
t=enable transponding reporting for Detections Section 4
c=disable transponding reporting for Detection Section 5
t=enable transponding reporting for Detections Section 5
c=disable transponding reporting for Detection Section 6
t=enable transponding reporting for Detections Section 6
c=disable transponding reporting for Detection Section 7
t=enable transponding reporting for Detections Section 7
c=disable transponding reporting for Detection Section 8
t=enable transponding reporting for Detections Section 8
Table 1: BXP88 Option Switches