4.5. Configuration of the switching-modes at DIGISPEED DS1/V2

To set a switching-mode of the DIGISPEED use the switches DIP1 and DIP2 of the fourfold DIP -
Switch. It is located behind the drilling in the transparent sheet on the device's right side.
To adjust the dip-switch use a small screwdriver or an bent paper clip.
switching-
mode
1
2
3
4
Note:
The cion figurationof the DIP-switches 3+4 must not be changed, both have to be set
to OFF.

5. Commisioning

The device is snapped onto the "EN carrier rail" in the switchboard (see chapter ""9. Dimensions"" on
page 14). Through the grounded assembly board and it's electrical connection to the EN carrier rail, the
disturbances are optimally grounded onto the cover. All cable connections have to be realized in a cold
state Connect the DIGISPEED at first with the shortest possiblew over-aroousing-time (run relais or
switchingdevices without flywheeling diode) and switch on the device. Increase the overenergizing
time in small steps 8regarding the recovery time) until no further improvement of switchimng behaviour
can be detected. Thenb switch back to the last overenergizing time with a detectable improvement of
the switching behaviour. To run the unit with a higher load does not make any sense since it only
causes a quicker using up. An optimal adjusted over-energizing time on the contrary will cause no
using up aboive average.
Attention: The connection to a lightbulb, an ohmic consumer, a valveplug with built in
LED or Zener-Diode at the output of the DIGISPEED is not allowed and can
cause thge destruction of the device.
Interrupting the connection between the DIGISPEED and a switching-link while
being under load can also cause the device's destruction. Try to avoid absolutely a
contact-switching or a connection that could be interrupted while being under load.
If this is not possible, a protection-switch has to be created at the switching-link.
For it's very high switchingperfomanbce, the DIGISPEED is not resistant against short
circuits. Therefore take care to do the complete comissioning in cold state.
Ausgabe: August 04
DIP 1
DIP 2
off
off
on
off
off
on
on
on
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
Digitaler Schaltbeschleuniger
DIGISPEED DS1/V2
DIP 3
DIP 4
off
off
off
off
off
off
off
off
Site web : www.hvssystem.com
Seite: 11