Checking the Installation
The show environment table command displays the temperature and voltage thresholds for each of
the three RSP7000 temperature sensors, for each monitored status level: low critical, low warning,
high warning, and high critical. The slots in which the RSP7000 can be installed are indicated in
parentheses (2 and 3). Also listed are the shutdown thresholds for the processor boards and power
supplies. An example of the show env table command follows for both the Cisco 7000 and
Cisco 7010:
The show environment all command displays an extended report that includes the arbiter type,
backplane type, power supply type (AC or DC), wattage and status, the number and type of
intermittent power failures (if any) since the system was last powered on, and the currently measured
values at the RSP7000 temperature sensors and the power supply voltages. An example of the
show env all command follows for both the Cisco 7000 and Cisco 7010:
24 Installing the RSP7000 Upgrade Kit in the Cisco 7000 Series Routers
RSP7000#sho env table
Sample Point
LowCritical
HighCritical
CI(6) Inlet
CI(6) Hotpoint
CI(6) Exhaust
+12 Voltage
10.90
+5 Voltage
4.61
-12 Voltage
-10.15
+24 Voltage
20.38
2.5 Reference
Shutdown power supplies at
RSP7010#sho env table
Sample Point
LowCritical
HighCritical
CI(4) Inlet
CI(4) Hotpoint
CI(4) Exhaust
+12 Voltage
10.90
+5 Voltage
4.61
-12 Voltage
-10.15
+24 Voltage
20.38
2.5 Reference
Shutdown power supplies at
RSP7000#sho env all
Arbiter type 1, backplane type 70x0 (id 5)
Power supply #1 is 700W (id 2), power supply #2 is removed (id 3)
Active fault conditions: none
Active trip points: none
Dbus slots:
card
CI(6)
Shutdown temperature source is 'hotpoint' on CI(6),
requested CI(6)
+12V measured at 12.12
+5V measured at 5.13
-12V measured at -11.84
+24V measured at 24.06
+2.5 reference is 2.49
LowWarning
44C/111F
54C/129F
11.61
4.94
-10.76
21.51
2.43
70C/158F
LowWarning
11.61
4.94
-10.76
21.51
2.43
70C/158F
0123456
X
X
inlet
hotpoint
21C/69F
30C/86F
HighWarning
50C/122F
60C/140F
12.82
13.38
5.46
5.70
-13.25
-13.86
26.42
27.65
2.51
HighWarning
44C/111F
50C/122F
54C/129F
60C/140F
12.82
13.38
5.46
5.70
-13.25
-13.86
26.42
27.65
2.51
exhaust
22C/71F