Step 2
Create the DHCP pool, including the necessary parameters such as default router and name server. A DHCP scope
example is as follows:
ip dhcp pool <pool name>
network <IP Network> <Netmask>
default-router <Default router>
dns-server <DNS Server>
Where:
<pool name> is the name of the DHCP pool, such as AP702
<IP Network> is the network IP address where the controller resides, such as 10.0.15.1
<Netmask> is the subnet mask, such as 255.255.255.0
<Default router> is the IP address of the default router, such as 10.0.0.1
<DNS Server> is the IP address of the DNS server, such as 10.0.10.2
Add the option 60 line using the following syntax:
Step 3
option 60 ascii "VCI string"
For the VCI string, "Cisco AP c702". The quotation marks must be included.
Step 4
Add the option 43 line using the following syntax:
option 43 hex <hex string>
The hex string is assembled by concatenating the TLV values shown below:
Type + Length + Value
Type is always f1(hex). Length is the number of controller management IP addresses times 4 in hex. Value is the IP
address of the controller listed sequentially in hex.
For example, suppose that there are two controllers with management interface IP addresses, 10.126.126.2 and 10.127.127.2.
The type is f1(hex). The length is 2 * 4 = 8 = 08 (hex). The IP addresses translate to 0a7e7e02 and 0a7f7f02. Assembling the
string then yields f1080a7e7e020a7f7f02. The resulting Cisco IOS command added to the DHCP scope is option 43 hex
f1080a7e7e020a7f7f02.
13
Access Point Specifications
Table 2
lists the technical specifications for 700 series access points.
Table 2
Access Point Specifications
Category
Dimensions without
mounting bracket
(LxWxD)
Weight
Operating temperatures 32 to 104 degrees F (0 to 40 degrees C)
Storage temperature
Operating humidity
Storage humidity
Antennas
Compliance
24
Specification
7 x 7 x 2 in (177.6 x 177.6 x 50.4 mm)
1.06 lb (0.48 kg)
–22 to 158 degrees F (–30 to 70 degrees C)
10% to 90% (noncondensing)
5% to 95% (noncondensing)
AP70xI: Integrated
The 700 series access point complies with UL 2043 for products installed in
a building's environmental air handling spaces, such as above suspended
ceilings.