Digiway P750F Інструкція з експлуатації - Сторінка 9
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Відкривач воріт Digiway P750F. Digiway P750F 16 сторінок. Sliding gate motor
e) Make sure F-code is connected.
f)
Power on again, push and hold CLS button for about 5 seconds until both OPENLED (green)
and CLSLED (Red) is solid on, release CLS button, gate will start closing at low speed.
g. Gate hit closed limit and stop, short delay, then start opening at low speed.
h) While in this opening cycle, if push and release PED button, that current position will be saved
as pedestrian open position.
i)
When gate hit opened limit and stop, all setting is finished
j)
Test gate by push buttons on board, if gate position is not right, then redo it again from step f.
5.3 MOD4: -- F-Code with one N/O limit switch: DIP2 on and DIP4 on
Mode-4 Only one limit switch required N/O, proxy switch or mechanical limit switch.
OLM---Open Limit Switch input as manual release protection input—option. CLM --- Close
Limit Switch Input N/O.
In this F-code mode, gate how to stop? F-code only determine the slow down point. Gate is
controlled by limit switch, or max. motor running time--- which is motor low speed running time
in learning cycle, plus 5 seconds extra. For example, if gate open take 30 seconds in learning
cycle/low speed, then max running time is 35 seconds
Either in closed or opened positions, as long as moved gate and limit switch status changed,
next operation will be in low speed and automatically back to normally after two operations.
a)
Mounting motor
b) Moving gate in middle position. Power up, touch limit or proxy switch by screw drive, close
LED will on. Open limit is used as manual release protection input---option.
c) Set up limit stopper potions. When Limit switch stopper touch limit and travel another 30 to
50mm, gate should hit mechanical stopper --- HEAVY DUTY MEHCNCAL STOPPER
MSUT BE INSTALLED.
CLOSED LIMIT SET UP.
Push gate against gate closed stopper and move limit stopper from limit switch active position
towards to gate closing direction for 30-50mm, which is the closed limit switch stopper
position. Use tek screw fix the limit stopper on gate bottom rail.
.
OPENED LIMIT SET UP.
Push gate against gate opened stopper and move limit stopper from limit switch active
position towards to gate opening direction for 30-50mm, which is the opened limit switch
stopper position. Use tek screw fix the limit stopper on gate bottom rail.
d) Push Open button, gate should open. If gate close, then swap any inverter output.
e) Make sure F-code is connected.
f)
Push and hold CLS button for about 5 seconds until the OPNLED and CLSLED both solid on,
then release CLS button. gate will start closing at low speed.
g). Gate hit closed limit and stop, short delay, then start opening at low speed.
h) While in this opening cycle, if push and release PED button, that current position will be saved
as pedestrian open position.
i)
When gate hit opened limit and stop, all setting is finished
j)
Test gate by push buttons on board, if gate position is not right, then redo it again from step f.
P750V5.0 industrial gate motor manual
9
.