B.1.1.1 RECOGNIZED HOST COMMANDS
"P" - This command is sent to the indicator to print the indicated display. The
"Z" - This command is sent to the indicator to zero the scale. The indicator will not
"T" - This command is sent to the indicator to tare the scale. The indicator will not
"G" - This command is sent to the indicator to revert to gross mode. The indicator
"N" - This command is sent to the indicator to revert to net. The indicator will not
"C" - This command is sent to the indicator to toggle among the configured units.
B.1.2 PRINT TICKET MODE
The Print Ticket Mode is designed specifically for a serial printer and is selected by setting
A6 to "1". Figure B-3 shows the fixed format of the print ticket.
For printers with limited buffers, this mode supports DTR pin handshaking. The DTR pin
from the serial printer is wired to the indicator's RXD pin which then functions as a CTS pin.
Figure B-4 shows a suggested cable diagram for interfacing to a serial printer. Refer to the
printer's user manual to confirm which pin is the DTR pin.
NOTES:
1. The TARE and NET fields are not printed unless a tare has been established in the
system.
2. The ID number field is not printed if it is disabled in A7 of the User Menu.
ID. NO.
123456
GROSS
25.00 LB
TARE
1.48 LB
NET
23.52 LB
FIGURE B-3. Print Ticket
indicator will not respond if the scale is in motion, positive overload or
negative overload.
respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it is not in gross mode or within the zero
range specified in F4 of the Setup Menu.
respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it displaying a negative gross value.
will not respond if the scale is in motion, positive overload or negative
overload. The indicator will also not respond if it is not in net mode.
respond if the scale is in motion, positive overload or negative overload. The
indicator will also not respond if it is not in gross mode or a tare has yet to be
established.
Appendix B
INDICATOR
CTS 2
TXD 3
S. GND
5
DSUB9
FIGURE B-4.
Cable Diagram for Indicator to Printer
PRINTER
3 RXD
20 DTR
7 S. GND
DSUB25