ABB DCS800-S01-0315-05 Посібник з прошивки - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник з прошивки для Приводи постійного струму ABB DCS800-S01-0315-05. ABB DCS800-S01-0315-05 20 сторінок.

ABB DCS800-S01-0315-05 Посібник з прошивки
Enabling a macro, continued
To use the parameter browser, either through the control panel, DriveWindow, or
DriveWindow Light, use the following parameters:
ApplMacro
Applrestore
MacroSel
ApplMacro (99.08) is used to select the desired macro. Applrestore (99.07) is used to
execute the command. First, change ApplMacro (99.08) to the macro of your choice from
the drop down box (in DW or DWL) or by using the arrow keys (in the control panel). Then
change the selection of Applrestore (99.07) from Done to Yes. When finished executing,
the drive will set this value back to Done. If using DWL, you may need to right click and
select upload to see this change. Verify the macro was loaded by observing the setting of
MacroSel (8.10). This signal shows the last macro loaded.
To use the wizard: IMPORTANT: New macros, as identified above, cannot be enable with
this method.
After connecting to the drive with DriveWindow Light (see Quick Guide for details), click on
the wizard. Then select the checkbox next to 2. Macro Assistant. Then select Next. At
the top of the page is the selection for parameter Application Macro (9908). Choose the
desired macro in the drop down box. Then click on Apply. The page will then fill in the
designations of the analog and digital inputs and outputs according to the macro selected.
Switching between macros – it's easier, starting with rev. 2.6
One new feature that has been implemented in rev. 2.6 is the ability to freely switch
between macros. For example, if you download the "standard" macro and then decide you
want to switch to "torque control," you can do so without concern. The macro will be loaded
without any affect on motor or tuning parameters. Please note, however, that the factory
macro will reset all parameters back to factory default.
Macro
C, D, E ...
Revision 2.6 allows you to freely switch between any macro, except factory, without changing
motor or tuning parameters. Factory macro resets all parameters back to default.
DCS800 Firmware manual supplement for North America (rev. 2.60, 2.70) Rev. b
(99.08)
(99.07)
(8.10)
Macro A
7
Macro B
5/30/2008