DC Power Cable Installation
Figure 2-1. Power Cable Routing into the Engine Compartment
4. Connect the black lead of the power cable to the nearest vehicle chassis ground point, which is
usually the central ground point near the battery (using the provided ring lug if necessary).
Shorten the black lead to remove any excess cable. (See Figure 2-2.)
NOTE Locate a good vehicle ground point. The vehicle central ground point provides the
best ground. If this is not available, the vehicle frame provides the best ground.
Optimum radio performance can only be achieved with a very low resistance ground
connection. Verify that the connections between the battery negative terminal,
vehicle chassis, and engine block have low resistance.
5. Place the fuse holder close to the battery. Ensure that it is not near any hot engine component.
Mount the fuse holder using its mounting hole and dress the wires as required.
6. Insert the stripped end of the red lead of the fuse holder into the ring lug hole and crimp it.
Connect the fuse holder red adapter lead plug to the mating receptacle on the red lead of the
power cable. (See Figure 2-2.)
7. Connect the power cable black lead directly to the vehicle chassis ground.
8. Connect the red lead ring lug from the fuse holder to the positive (+) battery terminal. Make sure
the adapter cable is connected to the main power cable red lead.
9. Carefully check that all connections are proper. Insert the fuse into the fuse holder and close the
cover. (See Figure 2-2.)
NOTE Failure to mount the red lead of the power cable kit directly to the battery may result
in severe alternator whine interference.
To Radio
Red Lead
Black Lead
Firewall
Grommet
Engine Compartment
FL08302460
3