Toshiba 22SKV Посібник з монтажу - Сторінка 10
Переглянути онлайн або завантажити pdf Посібник з монтажу для Кондиціонер Toshiba 22SKV. Toshiba 22SKV 12 сторінок.
Stripping length of the connecting cable
Terminal
block
Connecting
Power cord
cable
Model
Power source
Maximum running current
Plug socket & fuse rating
Power cord
Gas Leak Test
Valve cover
Electric parts
cover
Check places for
the outdoor unit.
Remote Control A-B Selection
• When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
• The remote control signal is not received when the settings of indoor unit
and remote control are different.
• There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil.
CHK
"00" will be shown on the display.
MODE
4. Press
during pushing
CHK
disappear and the air conditioner will turn OFF. The Remote Control B is
memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not "A" display.
3. Default setting of Remote Control from factory is A.
1110651154-EN.indd 8
1110651154-EN.indd 8
L N
1 2 3
40
40
30
30
Earth line
Earth line
Connecting
Power cord
cable
RAS-18SKV(R)
RAS-22SKV(R)
220 – 240 V Single phase, 50Hz
220 – 230 V Single phase, 60Hz
12A
13.5A
16A
H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
OTHERS
OTHERS
Check places for
the indoor unit.
• Check the fl are nut connections
for the gas leak with a gas leak
detector or soap water.
. "B" will show on the display and "00" will
CAUTION
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected fi rmly.
• If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to fi xed wiring: A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi xed wiring.
NOTE
: Connecting cable
• Wire type : H07RN-F or 60245 IEC66 (1.0 mm
"B" Display
"00" Display
PRESET
Test Operation
To switch the TEST RUN (COOL) mode, press RESET button for 10 seconds.
(The beeper will make a short beep.)
Hi POWER FILTER
RESET button
Auto Restart Setting
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
How to set the Auto Restart
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
• In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
8
2
or more)
FAN
PAP
TIMER OPERATION
RESET
2/15/10 9:39:42 AM
2/15/10 9:39:42 AM