Cruisair Zephyr ZF16 Короткий посібник - Сторінка 2
Переглянути онлайн або завантажити pdf Короткий посібник для Кондиціонер Cruisair Zephyr ZF16. Cruisair Zephyr ZF16 2 сторінки. Cooling-only zephyr (zf) air conditioning unit
Control Switch
and Thermostat
Connection
Seawater
Supply
Seawater
Line
Pump
Seawater
Strainer
Model
Nominal
Capacity
(Btu)
ZF5
5,000
ZF5CK
ZF10
10,000
ZF10CK
ZF12
12,000
ZF12CK
ZF16
16,000
ZF16CK
P.O. Box 15299 • Richmond, VA 23227-0699 USA • 804-746-1313 • Facsimile: 804-746-7248 • [email protected] • www.tmenviro.com
2000 N. Andrews Ave. Ext. • Pompano Beach, FL 33069-1497 USA • 954-973-2477 • Facsimile: 954-979-4414 • [email protected]
Fleets Industrial Estate • 26 Willis Way • Poole, Dorset BH15 3SU, England • +44(0)870 3306101 • Facsimile: +44(0)870 3306102 • [email protected]
®Taylor#Made is a registered trademark of Nelson A. Taylor Co., Inc.; the Taylor Made Group logo is a trademark of Taylor Made Group, Inc.; the Cruisair logo is a registered trademark and the Taylor Made Environmental logo
is a trademark of Taylor Made Environmental, Inc.
Discharge
Grill
Insulated
Flex Duct
To AC
Power
Zephyr Self-Contained
Air Conditioning Unit
Overboard
Discharge
Condensate
Drain
Return
Air
Grill
Valve
Thru-hull
Fitting
TECHNICAL SPECIFICATIONS
Height
Width
(in/mm)
(in/mm)
11.1/282
16/407
11.6/294
12.9/328
20/508
12.9/328
20/508
13.5/343
20/508
ZF Installation Guidelines
The following is a simplified explanation of the steps involved in installing
the Zephyr (ZF) air conditioner. Make sure you refer to the complete
Installation Manual when actually installing the system.
1. Select the Location. The Zephyr unit is normally mounted low in a
closet, under a vee-berth or settee, or any other out-of-the way location.
Cool air is carried through the insulated flexible ducting to a discharge air
grill located on a wall as high as possible in the compartment. Seawater is
pumped through the unit from an underwater thru-hull fitting and is
discharged overboard. The switch assembly is mounted on a convenient
wall in the compartment, no more than 10 ft. from the Zephyr unit. It's
recommended that the components be placed in the appropriate locations
before starting with the installation, to make sure everything fits.
2. Install the Seawater Plumbing Components. The seawater pump must
be mounted in the bilge below the waterline, and seawater is piped from a
bronze thru-hull fitting through a shut-off valve and strainer to the pump.
From there, water is piped upwards through the Zephyr unit's condenser,
and then to an overboard discharge fitting above the waterline.
3. Mount the Zephyr Unit. The Zephyr air conditioning unit is mounted on
a flat, horizontal surface, using the metal clips provided. The Zephyr blower
assembly can be rotated for either a horizontal or vertical discharge.
4. Install Grills and Duct. The return air grill should be placed so there is
unobstructed air flow to the Zephyr unit's evaporator coil. The discharge grill
should be placed as high as possible. A flexible duct is provided to carry air
from the Zephyr unit to the discharge grill. If the dual duct option is required,
a plenum is used to split the air discharge so that air is carried to two
different grills.
5. Connect Electrical Wiring. Cut a hole for the switch assembly. Route
the electrical wiring, along with the copper thermostat capillary tube, to the
Zephyr unit. Mount the thermostat bulb in the return air path. Make wiring
connections using the wiring schematic.
6. Hook Up the Condensate Drains. Attach plastic hose to either or both
of the condensate drain plugs in the pan beneath the unit. Route to an
overboard discharge or sump.
7. Attach Hose Connections. The seawater hoses are secured in place
using double/reversed hose clamps.
Depth
Weight
(in/mm)
(lb/kg)
39.6/18
11.6/294
41.3/18.7
12.8/326
54/24.5
12.8/326
58.5/26.6
13.8/350
62/28.2
Voltage
Maximum
Frequency
Amps
115V, 60Hz
220V/240V, 50Hz
17.7
115V, 60Hz
220V/240V, 50Hz
115V, 60Hz
48.3
220V/240V, 50Hz
115V, 60Hz
220V/240V, 50Hz
Revised: 10-11-02
29
44
22
27
67
32
L-2031