Ariklima PD70-LAE Посібник користувача - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник користувача для Осушувач повітря Ariklima PD70-LAE. Ariklima PD70-LAE 4 сторінки.

b. When ambient temperature is higher than 5℃ and lower than 20℃, the
product will set the humidity to 60% automatically.
c. When ambient temperature is higher than 20℃ and lower than 27℃, the
product will set the humidity to 55% automatically.
d. When ambient temperature is higher than 27℃, the product will set the
humidity to 50% automatically.
WATER FULL
When the water tank is full, the indicating light will illuminate and the unit
will stop working until empty the water tank.
WARNING
1. When operating the dehumidifier, please do not set the humidity higher
than ambient humidity.
2. When indicating light which shows the water tank is full illuminates, please
pour the water out of the tank and put it back. Then the product will
resume working.
3. When the product shut down, please wait at least 3 minutes before
restarting the unit to prevent damaging the compressor.
4. The applicable operating temperature range for this unit is 5-32 .
5. If the dehumidifier can't start (the indicating light does not illuminate) or
the dehumidifier shut down unreasonably, please make sure whether the
plug is connected firmly to power supply. If the plug and power supply are
in normal condition, please wait for 10 minutes before restart the unit
(because it takes 10 minutes to reposition). If the unit still does not start
after 10 minutes, please ask your local distributor service station to repair.
6. When the dehumidifier is operating, it's a normal situation that the working
compressor may cause some heat and bring the ambient temperature up.
7. When the product is defrosting, related indicating light will illuminate. And
during the defrosting, the compressor will stop but the motor will keep
working.
4
8.The unit shows the ambient humidity when it's operating. If the ambient
humidity is higher than RH95%, the display shows "HI"; if the ambient
humidity is lower than RH35%, the display shows "LO"
DRAINING INSTRUCTION
Draining water can storage in the water tank, or be continuous drained by
PVC tube. (The PVC tube is not included in the product.)
USAGE OF WATER TANK
When dehumidifying, the condensing water may be
drained to water tank. And the unit will stop working
with indicating light illuminates when the water tank is
full of water, please pour out the water that time.
1. Take out the water tank as Fig 01 and pour
out the water.
2. Put the water tank back.
3. Press power key to turn on the unit.
CONTINUOUS DRAINAGE
1. Before continuous draining water, please take out
the water tank and plug a draining tube to draining
hole (see Fig 02.) Then put the water tank back.
2. Draining tube should place lower than the draining
hole to let water flow out.
Fig 01
Fig 02
5