Dinel Flexi Watch FLD-32 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Перемикач Dinel Flexi Watch FLD-32. Dinel Flexi Watch FLD-32 16 сторінок. Thru-wall level switch
Used symbols
To ensure maximum safety of control processes, we have defined the following safety instructions
and information. Each instruction is labelled with the appropriate pictogram.
Alert, warning, danger
This symbol informs you about particularly important instructions for installation and operation of
equipment or dangerous situations that may occur during the installation and operation. Not observing
these instructions may cause disturbance, damage or destruction of equipment or may cause injury.
Information
This symbol indicates particularly important characteristics of the device.
Note
This symbol indicates helpful additional information.
1 . B
aSiC dESCripTiON
Thru-wall level switch FLD–32 "Flexi Watch" is designed for indication of the presence of
(conductive or non-conductive) liquids through the wall of glass or plastic vessels. The sensitivity
and switching mode can be simply set up using "programming" wire or magnetic pen, depending
on the type of sensor used. The sensor housing is made of a flexible polyurethane material with
a self-adhesive layer and holes for fastening bands.
2 . T
EChNiCal SpECifiCaTiONS
T
EChNiCal SpECifiCaTiONS
Supply voltage
Current consumption (idle-circuit condition)
Switched current (min. / max.)
Residual voltage in the closed state
Max. switching frequency
Ambient temperature range
Diameter of the vessel for the attachment of the sensor
maximum thickness
of the vessel wall
Protection class
Housing material
Type of connection cable
Weight (including 2 m cable)
Weight (without cable)
4
conductive liquids
non-conductive liquids with Ɛ
6 ... 30 V DC
max. 0.6 mA
3.3 / 40 mA
max. 6 V
-20 ... +70 °C
min. 300 mm
8 mm
< 10*
3 mm
r
polyurethane
PUR 3 x 0.14 mm
about 40 g
FLD-32
1 Hz
IP 67
2
10 g
© Dinel, s.r.o.