Aeotec AEOEZW112 Посібник із швидкого старту - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Аксесуари Aeotec AEOEZW112. Aeotec AEOEZW112 6 сторінок.

Aeotec AEOEZW112 Посібник із швидкого старту
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. Th
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Inclusion
1. Remove the backplate
2. Press the button on the back of the sensor once.
Exclusion
1. Remove the backplate
2. Press the button on the back of the sensor once.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is
significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller th
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the
device. To wakeup the device please perform the following action: Press the Action Button once, which will trigger sending out the Wake up notification command
press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a differen
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are alw
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive th
same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the de
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same log
http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW112
Maximum
Description
Nodes
5
Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.
sensor binary report, basic set or notification report command can be sent in this group when the
Sensor is triggered.
30-09-2020 13:12
Pagina 3 van 6