If you're using an existing gateway (ie. Vera, Smartthings, ISY994i ZW, Fibaro, etc):
You may need to refer to your gateway's method of including devices if you do not know how to pair a Z-Wave
device. You may use any gateway to perform an unpair/removal on TriSensor even if they are not paired together to
factory reset TriSensor.
1. Put your primary Z-Wave gateway into unpair mode, your Z-Wave gateway should confirm that it is waiting to
remove a device
2. Press the Action Button on your TriSensor 3x times within 2 seconds. The LED on TriSensor will become a solid
purple color.
3. If your TriSensor has been successfully removed from your network, the LED will flash white, green, white, green
(white, then green 2x times).
Advanced configurations for TriSensor.
You may also view our engineering sheet for TriSensor here:
https://aeotec.freshdesk.com/helpdesk/attachments/6064224662
(https://aeotec.freshdesk.com/helpdesk/attachments/6064224662)
Monitoring motion.
When TriSensor detects a motion event it will automatically send a notification report to Group 1 which is usually
automatically set to report to your gateway upon pairing your TriSensor.
Command Class
Command
Type
Event
By default, your sensor will time out after 240 seconds, for better use as a presence sensor, you can retrigger the
motion sensor to reset its timeout back to 240 seconds after 30 seconds. These settings are configurable.
1. Motion re-trigger time.
This configures the delay time before you can retrigger the PIR sensor, if the re-trigger happens between retrigger
time and clear time, this will reset the clear time clock. If this is disabled, you must wait until motion clears to trigger
motion again.
This setting is used as a presence sense and works together with Parameter 2. This will also help with conserving
battery report as if you re-trigger before clear time ends, TriSensor will not send a report.
Parameter #
Size
1
2
DEFAULT SETTING = 30
https://aeotec.freshdesk.com/support/solutions/articles/6000195459-trisensor-user-guide-
COMMAND_CLASS_NOTIFICATION
NOTIFICATION_REPORT
HOME_SECURITY (0x07)
HOME_SECURITY_MOTION_DETECTION_UNKNOWN_LOCATION (0x08) /
HOME_SECURITY_NO_EVENT (0x00)
Value
0
1-32767
TriSensor user guide. : Aeotec
Description
Disable Motion Re-Trigger.
Delay time in seconds.