Aeotec Water Sensor 7 Pro Посібник користувача - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник користувача для Аксесуари Aeotec Water Sensor 7 Pro. Aeotec Water Sensor 7 Pro 14 сторінок. Water sensor
Також для Aeotec Water Sensor 7 Pro: Посібник (3 сторінок), Посібник із швидкого старту (8 сторінок), Посібник користувача (9 сторінок), Посібник користувача (13 сторінок), Посібник користувача (9 сторінок)

Aeotec Water Sensor 7 Pro Посібник користувача

4 SOFTWARE FUNCTION DEFINITION

User Behavior Interaction

4.1
User behavior
Power OFF
Power ON
Make Magnet away or near
Click tamper switch once
Click tamper switch twice
Click tamper switch three
times quickly
Click tamper switch 5 times
quickly
Press and hold tamper switch
for 5 seconds
AEOTEC User Manual
Out of the Z-Wave network
Cut the power.
Send Inclusion Requests for SmartStart
Learn Mode.
LED will flash red 5 times, which means it's
out of the Z-Wave network.
If gateway is adding the device succeeds
through SmartStart, LED will light up green
for 2 seconds
If Adding fails, LED will off. Device will
auto-reset and then activate SmartStart
Learn Mode again.
LED will flash red once.
1.Reserved
LED will flash green once.
2.Exit Classic Inclusion Learn Mode:
If tamper switch is clicked again during the
Classic Inclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Device will auto-reset and then activate
SmartStart Learn Mode again.
Reserved
1.Send Node Info for Adding.
LED will blink green and red for 30s until it
is added into the network.
If Adding succeeds, LED will light up green
for 2 seconds
If Adding fails, LED will turn off. Device will
auto-reset and then activate SmartStart
Learn Mode again.
2.Exit Classic Inclusion Learn Mode:
If tamper switch is clicked again during the
Classic Inclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Device will auto-reset and then activate
SmartStart Learn Mode again.
Reserved
Factory Reset.
push the tamper for 5 seconds until the RED
LED blinks once. Then release tamper and
push it again for 5 seconds while the RED
LED is blinking until the GREEN LED blinks
once.
In the Z-Wave network
Cut the power.
Send Wake Up Notification.
LED will become flash green once, and
device will wake up for 15 seconds.
Trigger Association function.
Refer to Section 4.7 and 4.14 for details
about Association function.
LED will flash red once.
1.Issue Wake Up Notification and stay
awake for 15 senconds unless put to sleep
by Wake Up No More Information frame.
LED will flash green once.
2.Exit Classic exclusion Learn Mode:
If tamper switch is clicked again during the
Classic exclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Start a link test with controller (When
activated by configuration parameter #5).
If succes, LED will blink green two times
If failure , LED will blink red two times
1. Send Node Info for Removing.
LED will blink green and red for 30 seconds
until it is removeed from the network.
If Removing succeeds, LED will light up green
for 2 seconds
If Removing fails, LED will turn off.
2.Exit Classic exclusion Learn Mode:
If tamper switch is clicked again during the
Classic exclusion Learn Mode, the Classic
Learn Mode will exit. LED will turn off.
Toggle configuration parameter 1 setting
value from 0/1
Factory Reset.
push the tamper for 5 seconds until the RED
LED blinks once. Then release tamper and
push it again for 5 seconds while the RED
LED is blinking until the GREEN LED blinks
once.
Page 7