8. SERIAL OUTPUT
Specifications
RS-232 output for the transmission of the weight data
ASCII code
Baud 4800 (selectable from 600 - 9600)
Connector:
9 pin (female)
Pin 2:
RECEPTION
Pin 3:
TRANSMISSION
Pin 5:
GND
8.1 TRANSMISSION MODES
The transmitted data format varies depending on the selected transmission mode (see section 7.4).
P Prt and P Auto
Totalisation Mode
In the normal weighing operations when one is accumulating the weight the data format is the following:
When the totals are recalled from the storage the data format is the following:
Counting Mode
In the counting operations when the PRINT/M+ key is pressed the data format is the following:
Percentage Mode
In the percentage operations when the PRINT/M+ key is pressed the data format is the following:
Progressive of totalisations
GS for gross weight, NT for net weight
<CR><LF>
<CR><LF>
Progressive of totalisations
Total net weight
<CR><LF>
<CR><LF>
Number of pieces
Average piece weight
GS for gross weight, NT for net weight
<CR><LF>
<CR><LF>
Percentage of weight
<CR><LF>