Ariston 60 cm Посібник з експлуатації - Сторінка 31

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Холодильник Ariston 60 cm. Ariston 60 cm 47 сторінок.

Ariston 60 cm Посібник з експлуатації

5.6 Troubleshooting:

FAULT
Fails to switch on.
Compressor fails to start.
Compressor runs but
appliance fails to cool.
Compressor unable to
start.
Water under crisper
drawers.
Water on floor.
Compressor fails to stop.
Compressor fails to start.
Door open alarm sounds
continuously.
Display switches off
occasionally.
For No-Frost:
Compartments are not
very cold.
For No-Frost: Refrigerator
compartment not cold
enough.
For No-Frost: Refrigerator
compartment too cold -
food tends to freeze.
Service Manual
NEW ARISTON 60 cm PLATFORM
- Check voltage on mains socket outlet.
- Check power cord.
- Check continuity of windings.
- Check operation of Klixon relay.
- Faulty PCB.
- Appliance set to OFF.
- Compressor is cold - check refrigerant charge.
- Compressor is very hot - Check for traces of oil or refrigerant circuit
is blocked.
- Check for possible faulty compressor.
- Faulty Klixon relay.
- Faulty compressor.
- Mains voltage too low.
- Drain hole blocked.
- Container or wrapping paper touching refrigeration walls.
- Condensation collection bowl ruptured.
- Water drain tube incorrectly positioned.
- Condensation collection bowl not in contact with compressor.
- Faulty thermostat.
- Incorrectly positioned thermostat.
- Unsuitable electrical installation on Klixon.
- Door closure fault.
- Refrigerant circuit insufficient charge or blocked.
- Damaged compressor.
- Check Thermostat/PCB.
- No magnet in door.
- Faulty PCB.
- Door is distorted.
- Check display cable.
- Check display PCB.
- Evaporator coil clogged with ice.
- Check thermo fuse.
- Check heating elements.
- Chilled air suction fan motor.
- Ice has formed in the duct between the refrigerator and freezer
compartments.
- Check temperature probes.
- Damper does not close properly
Edition
2006.06.15
REMEDY
E
Language
English
N
31