Whirlpool 8182042 Інструкція з використання та догляду - Сторінка 6

Переглянути онлайн або завантажити pdf Інструкція з використання та догляду для Пральна машина Whirlpool 8182042. Whirlpool 8182042 44 сторінки. Front-loading automatic washer

Recommended installation spacing for cabinet
installation
The dimensions shown are for the recommended spacing.
For cabinet installation, with a door, the minimum ventilation
openings in the top are required.
7" (17.8 cm)
7" (17.8 cm)
4"
(10.2 cm)

Drain System

The washer can be installed using the standpipe drain system
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. (See
"Alternate Parts.")
1
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2
in. (5 cm). The minimum carry-away capacity can be no less than
17 gal. (64 L) per minute.
The top of the standpipe must be at least 30 in. (76.2 cm) high
and no higher than 96 in. (2.4 m) from the bottom of the washer.
6
31½"
1"
1"
27"
1"
(80.0 cm)
(2.5 cm)
(2.5 cm)
(68.6 cm)
(2.5 cm)
30" min.
(76.2 cm)
2
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 30 in. (76.2 cm) above the
9"
(22.9 cm)
floor.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be
purchased separately. (See "Alternate Parts.")
The siphon break must be a minimum of 28 in. (71 cm) from the
bottom of the washer. Additional hoses might be needed.

Electrical Requirements

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
A 120-volt, 60-Hz., AC-only, 15- or 20-ampere, fused
electrical supply is required. Time-delay fuse or circuit
breaker is recommended. It is recommended that a separate
circuit serving only this appliance be provided.
This washer is equipped with a power supply cord having a 3
prong ground plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, ground-type outlet, grounded
in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
28" min.
(71 cm)
30" min.
(76.2 cm)
1
WARNING
Electrical Shock Hazard
2