l/0" P
(?.2 mm)
pltre Plug
checking
inlet gas
pressure)
l/2" -
(12.7 mm)
gas SUPPLY
line (black
iron pipe)
t
/
flexible
connector
(use A.G.A.
desi n-
3
certi ied
connector)
\
L
W
If the dryers are installed
in a
confined
area such as a bathroom
or
closet, they must be exhausted
to the
outside and provision
made
for
enough
air for combustion
and
ventilation.
(Check
governing
codes
and ordinances.
Also refer to the
section
of this instruction
covering
"Recessed
and closet installations.")
Electrical
requirements
If codes
permit and a separate
grounding
wire is used, it is
recommended
that a qualified
electrician
determine
that the
grounding
path is adequate.
OBSERVE ALL GOVERNING
CODES AND ORDINANCES.
A 120-volt, 60-Hz, AC-only,
1.5 or
20-ampere
fused electrical
supply is
required.
Time-delay
fuse or circuit
breaker
is recommended.
It is
recommended
that a separate
circuit serving only these appliances
be provided.
Electrical
Shock Hazard
l
Electrical
ground
is required
on
this appliance.
l
Do Not ground
to a gas pipe.
l
Do Not modify
the power supply
cord plugs. If plugs will not fit the
outlet, have a proper
outlet
installed
by a qualified
electrician.
l
Do Not have a fuse in the neutral
or grounding
circuit.
A fuse in the
neutral or grounding
circuit could
result in an electrical
shock.
l
Do Not use an extension
cord
with this appliance.
l
Check
with a qualified
electrician
if you are in doubt as
to whether
the appliance
is
properly
grounded.
Failure to follow these instructions
could result in serious injury or
death.
Kz+;rdmended
grounding
For your personal
safety, these dryers
must be grounded.
Each dryer is
equipped
with a power
supply cord
having
a 3-prong
grounding
plug. To
minimize
shock hazard,
the cords
must be plugged
into mating
3-prong
grounding-type
wall receptacles,
grounded
in accordance
with
National
Electrical
Code ANWNFPA
70 -
latest edition"',
and all local
codes and ordinances.
If a mating
wall receptacle
is not available,
it is
the personal
responsibility
and
obligation
of the customer
to have a
properly
grounded,
3-prong
wall
receptacle
installed
by a qualified
technician.
See Figure 1.
8 00
I 8 00
cord
Figure 1
Copies of the standards listed above may be
obtained from:
*American
Gas Association
11515 Wilson Boulevard
Arlington,
Virginia
22209
** National
Fire Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
Page 4