Whirlpool 3979171 Інструкція з монтажу Посібник з монтажу - Сторінка 6
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool 3979171. Whirlpool 3979171 8 сторінок.
DIRECT WIRE
OR POWER SUPPLY CORD
Three-wire power supply cord must be
four feet long and have three, No.-10
copper wires and match a three-wire
receptacle of NEMA Type 10-30R.
Direct wire power supply cable must be
prepared as shown in "Preparing the wire"
of the three-wire connection direct-wire
steps above.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
D.
Level & exhaust
the dryer
E.
Check operation
SURE CONNECT
Kits Make Installation Easy
Part #4396028
Kit Contains:
2- 4' vent sections with attached close elbows
1- Wall plate for close clearance installations
2- 4" clamps
.
Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.
Panel E
Where local codes Do Not permit
connecting cabinet-ground conductor to neutral wire:
4.
Remove center terminal block screw.
6.
Connect the other
wires to outer terminal
block screws. Tighten
screws.
7.
Tighten strain
relief screws.
8.
Insert tab of terminal block
cover into slot of dryer rear
panel. Secure cover with
hold-down screw.
9.
Connect a separate copper ground wire
from the external ground connector screw to
an adequate ground.
Dryer must be level to reduce noise and assure
proper performance.
Slide dryer onto cardboard or hardboard before
moving across floor to prevent floor damage.
1.
Move dryer close to its permanent location.
Leave enough room to connect exhaust vent. Remove
cardboard or hardboard from under dryer.
2.
Check levelness of dryer by placing a level on
top of dryer, first side to side, then front to back. If
dryer is not level, adjust dryer legs up or down.
If legs are not long enough to level dryer, order
Extended Dryer Feet Kit, Part No. 279810 (sold two
legs per kit), from your dealer.
1.
Check that you:
did not skip any steps.
installed all parts.
properly installed dryer legs.
leveled dryer.
have secured all exhaust vent joints with 4" clamps.
have all the tools you started with.
2.
Plug power supply cord into grounded outlet
or connect direct wire to power supply. Turn power
supply on.
Dura Safe
TM
Outlets, Tight Installations
TM
Vent Kit
Provides 2 1/2" clearance
between dryer and wall
Great for closet
Provides 4 1/2"
installations
clearance between
0"-18", 18"-29" or
dryer and wall
29"-50" periscopes
include one male
Snap-Lock fittings
snap-lock fitting,
one extra long
Total kit length
draw-band collar
8 feet
and one clamp
Additional vent can
be snapped between
Use when vent outlets
sections for
overlap or are offset
longer runs
Excess length can
be trimmed to fit
18"-29" and 29"-50" Periscope
Swivel collar
wall connection
Telescoping
sections
Beveled edges
allow corner
installations
18"-29" : Part #4396011
Periscopes For Offset
2
1
/
"
2
0"-18" : Part #4396037
18"-29" : Part #4396011
29"-50" : Part #4396014
0"-18" Periscope
Part #4396037
Sections separate,
fittings can face
same or opposite
Swivel collar
Extra long
band-clamp
for dryer
connection
29"-50" : Part #4396014
5.
Remove the appliance
ground wire (green with yellow
stripes) from the external
ground connector screw.
Connect appliance ground wire
and the neutral wire (white or
center) of the power supply
cord/cable under the center,
silver-colored terminal block
screw. Tighten screw.
4" clamp
3.
Using a 4" clamp,
connect exhaust vent to
exhaust outlet in dryer. If connecting
to existing exhaust vent, make sure
the vent is clean.
The dryer exhaust vent must fit over the dryer
exhaust outlet and inside the exhaust hood.
Make sure exhaust vent is secured to exhaust hood
with a 4" clamp.
4.
Move dryer into final position. Do not crush
or kink exhaust vent. Make sure dryer is level.
3.
Read the Use and Care Guide to fully
understand your new dryer. Select a full heat cycle
(not the air cycle) and start dryer. After five minutes,
open dryer door. You should feel heat inside dryer.
If dryer does not operate properly, check the
following:
electrical supply is connected.
house fuse is intact and tight; or circuit breaker
has not tripped.
dryer door is closed.
controls are set in a running or "On" position.
start button has been pushed firmly.
If dryer makes an unusual noise, check that the dryer
is level.
For more information,
or to easily place your
order, call
1-800-442-9991
To have your venting
professionally installed,
call
1-800-253-1301
for the nearest
authorized service
provider.
4" clamp