Whirlpool 3LCED9100 Інструкція з монтажу Посібник з монтажу - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool 3LCED9100. Whirlpool 3LCED9100 48 сторінок. Commercial he dryer
Також для Whirlpool 3LCED9100: Інструкція з монтажу Посібник з монтажу (48 сторінок), Інструкція користувача (5 сторінок)
INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed:
[] 200 mm (8") or 250 mm
[]
8 mm (-%o")socket wrench
(10") Pipe wrench
[]
Utility knife
[] 200 mm (8") or 250 mm
[] Vent clamps
(10") Adjustable wrench
[]
Sealing compound gun
[]
Flat-blade screwdriver
and sealing compound
(for
[]
Phillips screwdriver
installing new exhaust vent)
[] Adjustable
wrench that
[]
Pliers
opens to 25 mm (1 ") or
[]
Stiff-bladed putty knife
hex-head socket wrench
[]
Level
Parts supplied:
Remove parts bag from dryer drum. Check that all parts were
included.
[]
Foot boot (4)
[]
Dryer foot (4)
NOTE: The circuit diagram for this dryer is located inside the
lower front panel, within the Tech Sheets.
Technical
Specifications:
220 - 240 v, 50 Hz. AC
Clothes Capacity:
9 Kg Max.
Explosion
Hazard
Keep flammable
materials
and vapors,
such as petrol,
away from dryer.
Do not install in a garage.
Failure to do so can result in death, explosion,
or fire.
IMPORTANT: Observe all governing codes and ordinances.
[]
Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages, closets, or sleeping
quarters. Contact your local building inspector.
[]
Do not install on carpet.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Recessed
Area and Closet
Installation
Instructions
This dryer may be installed in a recessed area or closet. This
dryer must not be installed behind a lockable door, a sliding door,
or a door with a hinge on the opposite side to that of the dryer.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
If installed in a closet with a door, the minimum unobstructed
air
opening in the top and bottom is required. Louvered doors
with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation
Clearances
381 mm
T3
(15")
________
E::Z]ri-q...
0mm
(0")
_--_
0ram
(0")
Recessed front view
356 mm
(14") max
Closet
door
J
cl
/ .... I
.......
0ram
(0")
_l l_2s mr. 0")
Closet side view
Additional clearances for wall, door, and floor moldings may be required or if
external exhaust elbow is used.
(48 in._)
Front
view
(24 in. _ )
0
L
76 mm (3")
closet
door
76 mm (3")
*Opening is the minimum
for a closet door. Louvered
doors with equivalent air
openings are acceptable.