Whirlpool 3LWED4830FW Інструкція з монтажу Посібник з монтажу - Сторінка 13

Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool 3LWED4830FW. Whirlpool 3LWED4830FW 19 сторінок. 737 mm (29 inch) wide models – gas & electric

Whirlpool 3LWED4830FW Інструкція з монтажу Посібник з монтажу
Vent System Chart
(Long Vent Models Only)
Number of
90° turns
Type
or elbows
of vent
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
5
Rigid metal

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 102 mm (4") clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
Box/louvered,
or Angled hoods
36.6 m (120 ft.)
33.5 m (110 ft.)
30.5 m (100 ft.)
27.4 m. (90 ft)
24.4 m. (80 ft)
21.3 m (70 ft.)
305 mm min.
12" min.
(305 mm)
(12" min.)
305 mm min.
12" min.
(12" min.)
(305 mm)

MAKE GAS CONNECTION

1.
Connect gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
tape.
®
2.
Plan pipe fitting connection
A
B
A. 9.5 mm (3/8") flexible gas
connector
B. 9.5 mm (3/8") dryer pipe
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
Non-flared
B
male fitting
C
C. 9.5 mm (3/8") to 9.5 mm (3/8")
pipe elbow
D. 9.5 mm (3/8") pipe-to-flare
adapter fitting
Open valve
B
D
13