Gas connection to the dryer itself should be made by means of
a exible gas hose suitable for the appliance and gas category
in accordance with national installation regulations. If in doubt,
contact the gas supplier. It should be minimum 10 mm (3/8") ID.
A means of restraint should be used between the appliance and
the wall to prevent straining of the rigid gas supply when the
appliance is moved. An appropriate length of chain and a wall
hook is recommended.
The dryer gas inlet connection is a 10 mm (3/8") NPT thread. An
adapter is supplied for conversion to standard ISO.228-1 thread
10 mm (3/8" BSP).
Check for leaks by using an approved noncorrosive leak
detection solution. Bubbles will show a leak. Correct any leak
found. A pressure measurement tapping is provided on the gas
valve within the dryer, accessible after removal of the lower front
panel.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during any pressure testing of that system.

INSTALL LEVELING LEGS

1.
Prepare dryer for leveling legs
To avoid damaging oor, use a large at piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
2.
Screw in leveling legs
diamond
marking
Examine leveling legs, nd diamond marking. Screw legs into
leg holes by hand, use a wrench to nish turning legs until
diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its nal location. Leave enough room for electrical
connection and to connect the exhaust vent.

VENTING REQUIREMENTS

WARNING:
To reduce the risk of re or suffocation, this dryer MUST BE
EXHAUSTED OUTDOORS.
ADDITIONAL WARNING for Gas Dryers:
Forced ventilation of fresh air is required. The room
containing the dryer must have an adequate air supply for gas
combustion and drying operation. A window or equivalent
means of ventilation must be opened in the room when the
dryer is in use (an equivalent form of opening includes an
adjustable louver, hinged panel, or other means of ventilation
that opens directly to outside air).
If exhaust is connected to a commonly used exhaust system,
it is necessary to install ap valves or alternative adequate
countermeasures at each connection to prevent back ow of
dryer exhaust.
Exhaust air must not be connected to an exhaust channel of a
furnace.
IMPORTANT: The design of the ue system should ensure that
any condensate formed when operating the appliance is either
retained or subsequently evaporated or discharged. Following
these installation instructions should adequately meet this
requirement.
9