Whirlpool 3RAWZ480E Інструкція з монтажу Посібник з монтажу - Сторінка 5
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool 3RAWZ480E. Whirlpool 3RAWZ480E 21 сторінка. Electric and gas dryer
Також для Whirlpool 3RAWZ480E: Інструкція з використання та догляду (24 сторінок), Посібник з використання та догляду (28 сторінок)
Venting requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions
can result in death or fire.
WARNING:
To reduce the risk of fire,
this dryer must be exhausted outdoors.
10.2 cm (4 in.) heavy metal exhaust vent
and clamps must be used.
• The dryer exhaust air must not be
discharged into a flue which is used for
exhausting fumes from appliances
burning gas or other fuels. It must also
not be discharged into a gas vent,
chimney, wall, ceiling or other concealed
space of a building.
• Do not use an exhaust hood with a
magnetic latch.
• Do not install flexible metal vent in
enclosed walls, ceilings or floors.
• Use clamps to seal all joints. Exhaust
vent must not be connected or secured
with screws or other fastening devices
which extend into the interior of the duct.
Do not use duct tape.
IMPORTANT: Observe all governing codes
and ordinances.
Improper venting can cause moisture and
lint to collect indoors, which may result
in:
• Moisture damage to woodwork,
furniture, paint, wallpaper, carpets, etc.
• Housecleaning problems and health
problems.
Use a heavy metal vent. Do not use plastic
or metal foil vent.
Rigid metal vent is recommended to
prevent crushing and kinking.
Flexible metal vent must be fully extended
and supported when the dryer is in its final
position. Remove excess flexible metal
vent to avoid sagging and kinking that can
result in reduced airflow and poor
performance.
An exhaust hood should cap the vent to
prevent rodents and insects from entering
the home.
Exhaust hood must be at least 30.5 cm (12
in.) from the ground or any object that is in
the path of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing vent system, clean lint
from the entire length of the system and
make sure exhaust hood is not plugged
with lint. Replace any plastic or metal foil
vent with rigid metal or flexible metal vent.
Plan vent system
Typical exhaust installations
Typical installations vent the dryer from the
rear.
Other installations are possible.
clamp
elbow
dryer
exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out
the right side, left side, or through the
bottom.
Cover unused exhaust holes with
one of the following kits:
279818 (white)
279969 (pewter)
Contact your local dealer.
Failure to follow these instructions
can result in death, fire, electrical
shock, or serious injury.
standard rear
exhaust
Alternate installations for close clearances
wall
exhaust
hood
over-the-top
rigid metal or
installation
flexible metal
(also available with
vent
one offset elbow)
Venting systems come in many varieties.
Select the best type for your installation.
Two close-clearance installations are
shown. Refer to the manufacturer's
instructions.
WARNING
Fire Hazard
left or right
side exhaust
bottom exhaust
(not an option with
pedestal
installations)
periscope
installation
5